6. Timer
Examples
If ON and OFF times have both been set at the simple timer, operation
and display are as indicated below.
Example 1:
Start the timer with ON time set earlier than OFF time
ON Setting:
3 hours
OFF Setting:
7 hours
Hr
ON
AFTER
SIMPLE
Hr
AFTER
OFF
˚C
˚C
SIMPLE
SIMPLE
Example :
Start the timer with OFF time set earlier than ON time
ON Setting:
5 hours
OFF Setting:
hours
Hr
AFTER
OFF
˚C
˚C
SIMPLE
Hr
ON
AFTER
SIMPLE
˚C
˚C
SIMPLE
6.1.3. Auto Off Timer
■
This timer begins countdown when the air conditioner starts and shuts
the air conditioner off when the set time has elapsed.
■
Available settings run from 30 minutes to 4 hours in 30-minute intervals.
Note:
*1.
Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same
time.
*2.
The Auto Off timer will not operate when any of the following conditions
is in effect.
The timer is off; the system is in malfunction state; a test run is in prog-
ress; the remote controller is undergoing self-check or remote control-
ler check; the user is in the process of selecting a function; the user is
in the process of setting the timer; the system is under central control.
(Under these conditions, On/Off operation is prohibited.)
AFTER
TEMP.
MENU
BACK
MONITOR/SET
PAR-21MAA
CLOCK
2
1
1
At Timer Start
Display shows the timer's ON setting (hours
remaining to ON).
At 3 hours after timer start
Display changes to show the timer's OFF set-
ting (hours remaining to OFF).
The time displayed is OFF setting (7 hours) –
ON setting (3 hours) = 4 hours.
At 7 hours after timer start
The air conditioner goes off, and will remain
off until it is restarted.
At Timer Start
Display shows the timer's OFF setting (hours
remaining to OFF).
At hours after timer start
Display changes to show the timer's ON set-
ting (hours remaining to ON).
The time displayed is ON setting (5 hours) –
OFF setting ( hours) = 3 hours.
At 5 hours after timer start
The air conditioner comes on and will con-
tinue to run until it is turned off.
OFF
AUTO OFF
ON/OFF
2
ON/OFF
FILTER
4
DAY
CHECK
TEST
OPERATION
CLEAR
9
<How to Set the Auto Off Timer>
2
3
AFTER
1. Be sure that you are at a standard control screen, and that the Auto
Off timer indicator is visible in the display (at 1).
When something other than the Auto Off Timer is displayed, set it to
AUTO OFF TIMER using the function selection of remote controller
(see 8.[4]-3 (3)) timer function setting.
. Hold down the Timer Menu button 2 for 3 seconds so that the "Set
Up" appears on the screen (at 2).
(Note that each press of the button toggles the display between "Set
Up" and "Monitor".)
3. Press the appropriate Set Time button 1 as necessary to set the OFF
time (at 3).
4. Press the Filter
button 4 to lock in the setting.
Note:
Your entry will be cancelled if you press the Mode (Return) button
pressing the Filter
button
.
4
5. Press the Mode (Return) button 2 to complete the setting procedure
and return to the standard control screen.
6. If the air conditioner is already running, the timer starts countdown
immediately. Be sure to check that the timer setting appears cor-
rectly on the display.
<Checking the Current Auto Off Timer Setting>
4
5
TIMER
AFTER
1. Be sure that the "Auto Off" is visible on the screen (at
. Hold down the Timer Menu button 2 for 3 seconds so that "Monitor"
is indicated on the screen (at 4).
• The timer remaining to shutdown appears at 5.
3. To close the monitor and return to the standard control screen, press
the Mode (Return) button 2.
<To Turn Off the Auto Off Timer...>
●
Hold down the Timer On/Off button 9 for 3 seconds so that "Timer
Off" appears (at 6) and the timer value (at 7) disappears.
˚C
6
●
Alternatively, turn off the air conditioner itself. The timer value (at 7)
will disappear from the screen.
7
<To Turn On the Auto Off Timer...>
●
Hold down the Timer On/Off button 9 for 3 seconds. The "Timer Off"
indication disappears (at 6), and the timer setting comes on the dis-
play (at 7).
●
Alternatively, turn on the air conditioner. The timer value will appear at
7.
AFTER
˚C
6
Timer Setting
OFF
1
AUTO OFF
2
Timer Setting
OFF
1
AUTO OFF
).
1
7
˚C
AUTO OFF
AUTO OFF
7
OFF
˚C
AUTO OFF
before