KEY SWITCH

INDEX
CH2
KEY SWITCH TYPE 1 [AUTO-PP]\[PED]:
By selecting channel CH1 (key to the right), the AUTO-PP (open-close)
command is enabled, while by selecting channel CH2 (key to the left), the
PED (pedestrian opening) command is enabled.
KEY SWITCH TYPE 2 [OPEN]\[CLOSE]:
By selecting channel CH1 (key to the right), the OPEN (open only) command
is enabled, while by selecting channel CH2 (key to the left), the CLOSE
(close only) command is enabled.
KEY SWITCH TYPE 3 [AUTO-PP]\[STOP]:
By selecting channel CH1 (key to the right), the AUTO-PP (open-close)
command is enabled, while by selecting channel CH2 (key to the left),
the STOP (stop automation) command is enabled. After a STOP, a new
command is needed to restore operation of the automation.
I/O INTERFACE
I/O INTERFACE
IN
OUT
I/O INTERFACE TYPE 1 In=[AUTO-PP]\[PED] Out=AUX:
Input
Using the inputs IN1-COM or IN2-COM will activate the following commands:
IN1-COM:
(NO optically insulated input) Activates the command
Auto-PP (open-close)
IN2-COM:
(NO optically insulated input) Activates the PED command
(pedestrian opening)
Output
There are two outputs set to AUX function (which can be enabled simultaneously by
each remote control encoded as AUX - monostable 3" ON):
24V+
Output + 24V
(20mA max)
24V-
Output - 24V
NO:
Clean N.O. contact output (24V
C:
Clean contact output (common)
I/O INTERFACE TYPE 2 In=[OPEN]\[CLOSE] Out=AUX:
Input
Using the inputs IN1-COM or IN2-COM will activate the following commands:
N1-COM:
(NO optically insulated input) Activates the command
OPEN (opening only)
IN2-COM:
(NO optically insulated input) Activates the command
CLOSE (closing only)
Output
There are two outputs set to AUX function (which can be enabled simultaneously by
each remote control encoded as AUX - monostable 3" ON):
22
COMUNELLO ®Copyright 2017 - All rights reserved
24V+
24V-
NO:
C:
I/O INTERFACE TYPE 3 In=[AUTP-PP]\[STOP] Out=INDICATOR LIGHT:
Input
IN1-COM:
IN2-COM:
CH1
Output
There are two outputs set to INDICATOR LIGHT function that are activated
simultaneously, signalling the status of automation:
24V+
24V-
NO:
C:
Flashing light output
Output activated (ON)
Output deactivated (OFF)
I/O INTERFACE TYPE 4 In=[AUTP-PP]\[PED] Out=INDICATOR LIGHT:
Input
Using the inputs IN1-COM or IN2-COM will activate the following commands:
IN1-COM:
IN2-COM:
Output
There are two outputs set to INDICATOR LIGHT function that are activated
simultaneously, signalling the status of automation:
24V+
24V-
NO:
C:
Flashing light output
Output activated (ON)
Output deactivated (OFF)

FLASHING LIGHT:

The operation of each flashing light is defined by the control unit according
to the settings of the configurable parameters.
FUNCTIONAL CHARACTERISTICS (PARAMETERS)

AUTOMATIC OPERATION:

Using both the remote control and the accessory control devices connected
to the BUS with AUTO-PP function to open/close the gate, operation will
be as follows:
the first impulse opens the gate until the programmed stroke ends or until
the gate reaches its opening limit stop; the second impulse closes the gate;
if another impulse is sent before the end of the stroke or before one of the
two limit stops has been reached, the control unit reverses the movement
direction during both opening and closing.
1
O
N
DIP 1 OFF = Automatic Operation
NOTE: A variation of the dip-switches requires pressing the RESET button
1A max)
on the control unit to activate the new setting.
STEP-BY-STEP OPERATION:
Using both the remote control and the accessory control devices connected
to the BUS with AUTO-PP function to open/close the gate, operation will
be as follows:
the first impulse opens the gate until the programmed stroke ends or until
the gate reaches its opening limit stop; the second impulse closes the gate;
if another impulse is sent before the end of the stroke or before the opening
limit stop has been reached, the control unit stops the movement (even if
you have previously programmed the pause time). An additional command
activates a reverse stroke in the opposite direction; if you send a command
before the end of the stroke or the closing limit stop, the control unit always
stops movement. A further command activates a reverse stroke.
Output + for indicator light 24V
Output - for indicator light 24V
Clean N.O. contact output (24V
Clean contact output (common)
(NO optically insulated input) Activates the command
Auto-PP (open-close)
(NO optically insulated input) Activates the command
STOP (stop automation)
Output + for indicator light 24V
Output - for indicator light 24V
Clean N.O. contact output (24V
Clean contact output (common)
= gate moving
= gate open
= gate closed
(NO optically insulated input) Activates the command
Auto-PP (open-close)
(NO optically insulated input) Activates the command
PED (pedestrian opening)
Output + for indicator light 24V
Output - for indicator light 24V
Clean N.O. contact output (24V
Clean contact output (common)
= gate moving
= gate open
= gate closed
2
3
4
5
6
7
8
9
10
(20mA max)
1A max)
(20mA max)
1A max)
(20mA max)
1A max)