Comunello CU 24V 1M ONE Instrucciones De Uso página 24

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Input terminal for connection of the encoder with two non-polarised wires.
INDICATOR LIGHT:
The control unit allows the connection of a 24Vdc lamp for automation
status display via accessories connected to the BUS line with INDICATOR
LIGHT function (e.g.: I/O Interface set to INDICATOR LIGHT function – par.
SETTING THE ACCESSORY OPERATION (MODE) ).
24V+
24V-
NO:
C:
Flashing light output
Output activated (ON) = gate open
Output deactivated (OFF) = gate closed
1
2
3
4
5
6
7
8
9
10
AUXILIARY UTILITY OUTPUT (OUT AUX) ELECTRIC LOCK -
FLASHING LIGHT
The control unit has a dedicated output for piloting, alternatively, 24V
12W electric locks of the impulse type or 24V
the continuous type. If the output is programmed as an ELECTRIC LOCK
COMMAND, the command is activated at each initial opening movement
for about 3 sec. If the output is programmed as AUXILIARY FLASHING
LIGHT, it will be piloted by the control unit as a standard flashing light.
Output terminals for connection of the auxiliary utility programmable
alternatively as:
ELECTRIC LOCK COMMAND
AUXILIARY FLASHING LIGHT
NOTE: max. load 24V
1
2
3
4
O
N
DIP 7 ON = Auxiliary Flashing Light
DIP 7 OFF = Electric Lock Command
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to activate the new setting.
24
COMUNELLO ®Copyright 2017 - All rights reserved
1
2
3
4
5
6
7
8
9
10
Output + for indicator light 24VDC (20mA max)
Output - for indicator light 24VDC
Clean N.O. contact output 24VDC 1A max
Clean contact output (common)
= gate moving
5W flashing lights of
5W (continuous), 12W max. (impulse)
5
6
7
8
9
10
BUFFER BATTERY
The control unit allows connection of a buffer battery kit (code AC51) which
allows the gate to perform several complete open/close manoeuvres at
slow speed.
Input for connection of buffer battery kit.
NOTE: Use only ONE buffer battery kits (code AC51)
CHANGING THE OPERATOR ROTATION DIRECTION
The control unit is equipped with a slide-switch that allows you to set or
change the operator rotation direction.
Slide selector switch for controlling the rotation direction of the operator.
INV1
Invert Operator 1 Rotation
NOTE: A variation of the slide-switches requires pressing the RESET
button on the control unit to activate the new setting.
CONDOMINIUM OPERATION
In the condominium operation mode, during opening and pause, the
control unit does not respond to commands coming from accessories
connected to the BUS line with open-close function (AUTO-PP) and
from the remote controls. During the closing phase, instead, this opera-
ting mode inverts the movement.
1
2
3
4
5
6
7
8
9
O
N
DIP 2 ON = Condominium Operation Activated
DIP 2 OFF = Condominium Operation Deactivated
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to activate the new setting.
RELEASE STROKE
This function sends a closing command approx. for 1 second at the start
of an opening cycle: this facilitates release of the lock to allow correct
execution of the opening cycle.
1
2
3
4
5
6
7
8
9
O
N
DIP 8 ON = Release Stroke Activated
DIP 8 OFF = Release Stroke Deactivated
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to activate the new setting.
MASTER / SLAVE
The control unit can be set to MASTER or SLAVE operation. This allows
possible connection of the line of BUS accessories to a control unit set as
SLAVE for automations that envisage the use of systems that must work
in synchronous mode (e.g. double barriers).
1
2
3
4
5
6
7
10
10
8
9
10