Enable/Disable Opening Pre-Flash
Enable/Disable Fast Flash during Opening cycle
Enable/Disable Fast Flash during Closing cycle
Enable/Disable Flash during Pause
Operation test
Assign a text string for each key flashing light
I/O Interface
Operation test
Assign a text string for each I/O interface
Set the MODE (operation) of each I/O interface
Utility output
Set Electric lock activation time
Diagnostics
Display the number of Manoeuvres Performed
Display the number of Operator hours of operation
Display the number of System Life Hours
Display the number of Resets
Display the number of Stops (STOP commands)
Display the number of Encoder notches
FACTORY RESET
If there is need to restore the control unit to its factory settings, press
simultaneously the RESET, TX CODE, AUTOSET and STEP BY STEP
buttons, release only the RESET button (holding the others pressed), until
the AUTOSET led begins to flash. Now you can release the other buttons
(TX CODE, AUTOSET and STEP BY STEP), and the TX CODE led begins
to flash . Once TX CODE led stop flashing, wait until the AUTOSET led turns
on for a while and then its turning off will confirm the control unit resets all
parameters to their initial factory settings.
DIAGNOSTICS
Photocell (DS) management in case of a fault
The photocell management (DS) in case of a fault of AT LEAST ONE OF
THOSE ACQUIRED during installation will INHIBIT CLOSING of the gate
(excluding virtually all cases of controlled or automatic closing). If a photocell
previously acquired experiences a fault, the automation will stop, which will
only be able to open (for safety reasons), but will never be able to close,
except after:
1. Disabling of the safety devices (DS) via the DIP switch #10 (ON)
2. Reacquisition of the missing DS (with the same ID of the faulty device)
Disabling of the safety devices (emergency operation)
Disabling management of the DS (photocells, stops, etc.) allows the control
unit to "eliminate logically" the DS that are faulty/missing, but continuing
to manage consistently the settings of the functional DS installed on the
system. Essentially, disabling the safety devices (DS) does not eliminate the
photocells installed and that are functional (raising safety issues), but only
those that are no longer functional.
Reacquisition of the missing DS (fault repair)
If a photocell (DS) experiences a fault, the automation operates according
to the function set on the faulty DS (e.g.: if the photocell is set ON OPEN,
when the DS experiences the fault, the gate stops and will not restart until
disengaged, which will never occur, due to the presence of the fault). If you
do not want to intervene by disabling the DS via DIP switch #10, you will
have to repair the fault, i.e. replace the faulty DS with an equivalent one
having the same ID. Once you have reconnected the repaired DS, you
have to run the (DETECT) procedure again by
a. Pressing the RESET button in the control unit
b. DETECT via app COMUNELLO ONE
NOTE: By pressing the RESET button, all the accessories connected are
recognised, the HW parametres on the board (trimmer adjustments, DIP,
SLIDE, etc.) are checked again and the FIRST OPENING MANOUEVRE
is SET. If the gate is completely open (safety manoeuvre), this can cause
a stop on opening and a new command must be sent to close the gate.
BLACK-OUT MANAGEMENT
In the event of a power failure (or following the logic RESET, i.e.: pressure of
the key RESET on control unit), the system always makes a short opening
manoeuvre, followed by a closing manoeuvre in safety speed (receiving the
following command).
WARRANTY
Fratelli Comunello SpA provides a warranty for 24 months for the correct
functioning of the actuators from the date of manufacture, provided that
the performance specications indicated in the product instruction manuals
are respected. Free of charge repair and replacement of components
that are found to be faulty according to the indisputable judgment of the
company's technical staff shall be guaranteed at the sole discretion of
Fratelli Comunello Spa, and so excluding any claim for damages made
by others. Warranty material shall be returned to Fratelli Comunello S.p.a.
(1"..20")
headquarters carriage paid and will then be shipped to the customer
carriage unpaid. The material found to be faulty and returned to Fratelli
Comunello S.p.a. shall remain property of the Seller. Any cost resulting
from any work needed to repair the defect or to replace the material shall
be charged to the Buyer. No compensation shall be allowed for the period
of device inactivity. Work under warranty does not prolong the warranty
period. The defect of the product shall be reported by the Buyer within 8
(eight) days from its discovery or from the date of delivery of the goods,
under penalty of invalidation of the warranty. Such claim shall be notied
in writing.
Warranty does not cover:
Any product defect or damage that may have been incurred during
transport; any defect or damage arising from any fault and/or from
neglect, inadequacy and misuse of the electrical wiring in the Buyer's
property; any defect or damage caused by any repairs carried out by
non authorised personnel or by incorrect use/installation (with reference
to this, system maintenance is recommended every 6 months) or if
not original spare parts are used; any defect caused by chemicals or
atmospheric conditions. The warranty does not cover any cost neither
for consumable materials nor for alleged defects or convenient surveys.
Product Features Fratelli Comunello SpA products are subjected to
continue changes and improvements; their technical features and image
may therefore change without previous notice.
Competent court
Since the confitract of sale is confirmed by an Order Confirmation drawn
up in Rosà, any such dispute shall be settled by the laws of Italy and by
the court of Vicenza (VI).
FAQ
FAQ. Question
Can I use 24 VDC
operators without an
encoder?
Can I use 24 VDC
operators from other
manufacturers equipped
with an encoder?
Can I connect
accessories (flashing
lights, photocells, key
switches, etc.) from other
manufacturers?
FAQ. Question
NO. The ONE system necessarily requires
the use of 24VDC operators with encoder
to work properly, run precise movements
and ensure safety (obstacle detection).
NO. The ONE system requires the use
of ONE series geared operators that use
an encoder signal converter in order to
facilitate the installation of the encoder itself,
using only 2 non-polarized wires.
The ONE system requires the use of
ONE digital accessories (with on-board
intelligence) connected on the BUS line that
communicate with the control unit through
a proprietary communications protocol. The
use of third-party accessories, including
digital ones, is not compatible with the
system. You can use third-party devices
using the ONE I/O INTERFACE that lets you
manage N.O. push buttons, indicator lights
and external loads that can be enabled from
relays (with appropriate external support
relay), such as flashing and high-power
lights. The ONE control unit also features
a dedicated output OUT AUX that can be
programmed as an AUX FLASHING LIGHT
output (24 VDC max. 5W) or ELECTRIC
LOCK COMMAND (24 VDC max. 12W
pulse).
COMUNELLO ®Copyright 2017 - All rights reserved