FAQ. Question
FAQ. Question
Can I replace a generic
The control unit already installed on a
control unit of an
system can be replaced only if you also
automation already
replace all the other accessories and
installed with control unit
geared operators. In general, this is possible
ONE?
because a standard automation system has
more than 2 wires for each accessory (so
you can use two wires, normally those that
supply power, for the BUS line connection).
What happens if I assign
The control unit detects a conflict of
the same ID to two
communication between the accessories,
devices (accessories) of
disabling them. As a result, you can lock
the same family?
the gate in fully open position (for safety
reasons).
After I have connected
Check the connections to the operators.
everything and set the
Check safety fuse F2 connected to the
basic parameters through
operator power supplies to make sure it is
the dip-switches (manual
intact. Also check safety fuse F1 connected
adjustments), when I
to the transformer's primary winding. Check
press the STEP BY STEP
for the presence of mains voltage.
button, the operators do
CAUTION: we recommend that you always
not move the gate.
leave the gate semi-open when checking
operator movements.
I connected the
Check if the led TX and POWER BUS are
accessories to the BUS
on. If they are not, check the integrity of
line, but they do not
logic safety FUSE 3.
seem to respond to
commands.
I need to power an
If you need to have a direct 24 VDC
external radio receiver
supply at all times (utilities), you can use
or another 24 VDC low
the dedicated output OUT AUX (excluding
consumption device.
the LAMP AUX or ELECTRIC LOCK
How can I power it from
COMMAND AUX functions) that can deliver
the control unit?
up to 5W in continuous mode. To activate
this power supply, remove the board plastic
cover and bridge J1 with a specific jumper:
I cannot connect with the
Make sure you have slotted the K-ONE in
app to the control unit.
the specific connector in the centre of the
board. Check that a red led is on or flashing
on the side of the K-ONE. Make sure that
you have enabled WiFi on your device
(smartphone or tablet) and that you have
connected it to the network generated by
the K-ONE.
28
COMUNELLO ®Copyright 2017 - All rights reserved
FAQ. Question
I configured the system
with the app. I can no
longer change the basic
parameters through
the dip-switches of the
control unit.
I configured the system
through the manual
adjustments, but during
self-learning of the
stroke, the gate stops.
The remote controls
seem to have little power
in transmission, i.e. they
do not send the signal of
the remote control from
afar.
What happens if I invert
the "open" limit switch
with the "close" limit
switch?
Can I use the ONE
system to manage a
synchronised double
barrier?
J1
Can I use the ONE
system to manage a
double sliding gate?
In the MASTER-SLAVE
applications, where do I
connect the accessories
to the BUS?
Which are the dip-switches possible settings?
1
2
3
4
5
O
N
DIP 1 OFF = Automatic Operation
1
2
3
4
5
O
N
DIP 1 ON = Step-by-Step Operation
FAQ. Question
Once you have configured your system
through the app, the command is
automatically disabled by the physical
settings (hardware) in the board. Therefore
it is no longer possible to change the
settings of the system manually, which
is meant to ensure commissioning and
certification of the system. If you want to
change the settings, you need to access
the system again through the K-ONE or
apply the FACTORY RESET procedure and
reconfigure the system from scratch.
If the gate freezes, check the connections
of the encoder to make sure they are wired
to the corresponding inputs of the operator.
If the gate runs a brief inversion during
closure or freezes when opening (obstacle
detection), check the speed and sensitivity
levels on the trimmers. Try decreasing the
SENS trimmer and increasing the SPEED
trimmer.
Make sure that the 50Ohm impedance
terminal of the antenna is installed. Check
for the presence of the impedance terminal
even when using a coaxial cable (do not
leave the coaxial cable without terminal).
Check the charge level of the remote
control batteries (3.0V with a full charge).
If you invert the limit switches, the control
unit cannot properly detect the end
of the movement by intercepting the
corresponding limit switch. In this case, the
control unit searches for the mechanical
lock or the maximum stroke saved via
encoder count. This does not generate
malfunctions, but the system loses the
safeties linked to the presence of the limit
switches.
YES. To manage the double barrier
LIMIT-ONE, you have to use two ONE
control units, one for each barrier, setting
one as MASTER and the other as SLAVE
(using the dip switch #10 of the control
unit). In this way, the MASTER control
unit communicates with the SLAVE,
synchronising their movements.
YES. To manage a double slider FORT-
ONE, you have to use two ONE control
units, one for each slider, setting one
as MASTER and the other as SLAVE
(using the dip switch #10 of the control
unit). In this way, the MASTER control
unit communicates with the SLAVE,
synchronising their movements.
In synchronised applications (MASTER-
SLAVE), the accessories must be
connected only on the MASTER BUS line.
6
7
8
9
10
6
7
8
9
10