1.4.2 - Operator interface

Description
Modifying the direction of rotation.
When the tightening direction is ena-
bled, the lights are off. When the run
Direction of rota-
reverse direction is enabled, the red and
tion
green lights are flashing.
Entering the programming mode and
validate.
Programming
button
Changing parameter or increasing the
value. Reading the torque setting in con-
Button +
trol mode.
Changing parameter or decreasing the
value. Alternately reading the speed set-
Button -
ting (1 to 10), the rundown speed (rpm)
and the final tightening speed (rpm) in
control mode.
Showing that the number of cycles is
higher than the number programmed
and that it is time to perform control or
Maintenance
maintenance operations.
warning light
Showing that the parameter is selected.
For safety reasons an access code must
Access
code
be entered before modifying the param-
parameter light
eters.
Showing that the parameter for display-
ing and modifying the final torque value
and the torque unit is selected.
Torque
parame-
ter light
Showing that the parameter which,
when a torque value has been entered, is
Learning parame-
used for measuring the assembly speci-
ter light
fications and for optimising all the
adjustment parameters (rundown thresh-
old, speed, angle tolerance) is selected.
Tightening time and overheating are
then optimised for tightening accuracy.
Showing that the parameter is selected.
10 speed levels for adjusting speed got
Speed parameter
by learning. The rundown speed and the
light
tightening speed are adjusted at the
same time.
All parameters can be programmed and
saved using a PDA (Pocket PC). The
Communication
data transfer between both devices is
light
made through radio frequency waves
using Bluetooth protocol; the light is
flashing as long as the communication
lasts.
Displaying the tightening reports (OK,
NOK,
errors) and the main parameters of the
Display
tool.
EAP/EDP
Function
tightening
faults,
operating
Part no
6159936431
Issue no
06
Language English
Date
09/2009
24
Page
7 /
Tabla de contenido