Manual speed adjustment:
When it is not possible to learn the joint, it is possible to adjust the speed according the joint hardness. It is suggested to use angle
values of the following table. Angles are defined as the bolt rotation from 50% to 100% of the target torque.
Degrees from
0-10
50 to 100%
Speed level
1

1.2.7 - Parameter validation

To save the parameters, press
The tool goes back in tightening mode and is ready to tighten.
By default, if no key is pressed during 60s, the tool goes back in tightening mode without saving parameters.
To quit quickly the programming mode without saving parameters:
1 From the parameter choice mode, press
until "ESC" is displayed.
2 Press
to validate.

2 - PROGRAMMING USING THE CVIP Pocket SOFTWARE

You can programme the tool using a PDA with the CVIP Pocket software. With the PDA, you can read, modify and save all the
tool parameters, as well as create new tightening programmes and download a programme in the tool.
With the CVIP Pocket software, you can also read the tightening results from a tool.
The wireless communication between the tool and the PDA is made using a Bluetooth protocol.
For further information, refer to the CVIP Poket software manual supplied with the software CD-ROM.
10-25
25-46
40-70
2
3
4
for at least 3 seconds.
or
EAP/EDP
70-105
105-147
147-189
5
6
189-245
245-297
7
8
9
>297
10
Tabla de contenido
loading

Tabla de contenido