1 - PROGRAMMING DIRECTLY ON THE TOOL

1.1 - Description

The tool has been designed for an easy, optimum, fast and secured start-up. The parameters directly programmable from the tool
are:
the access code which authorises parameter modification,
the tightening torque and its unit,
the learning mode,
the speed adjustment.

1.2 - Main programming procedure

1.2.1 - Programming mode

1 Press
for at least 3s to reach the programming
mode. The access code parameter is displayed (set
up to 0).
This step is disabled if the "Locked in programming" option has been selected through the PDA; in this case
the parameters cannot be modified directly from the tool. The tool displays
returns to the control mode.
2 Change this value using
code is displayed (122 by default).
continuous action -> fast scrolling
short action -> step by step modification.
The access code can be changed using the PDA (see
corresponding manual).
3 Press
to validate. If the access code is not correct, E201 is displayed and all the parameter LEDs light up
for a few seconds, then the tool returns to control mode.
EAP/EDP