Desoutter EAP1.5-15 Serie Manual Del Operador página 19

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
Error
Description
E12
Overheating of IGBT
E13
Engine not tuned
E201
Wrong access code
E300
Communication error with the PDA
- Size of received data over the
maximum authorized value
E301
Communication error with the PDA
- No start flag on the first byte of the
frame
E302
No
communication
Bluetooth module
E350
Communication error with the DTU
- Size of received data over the
maximum authorized value
E351
Communication error with the DTU
- No start flag on the first byte of the
frame
E352
Communication error with the DTU
- Tool frame is not understood by the
DTU
E353
Communication error with the DTU
- CRC error
E404
Exceeding of the current threshold
forced in the power bus. Overcurrent
on the power circuit (software cut)
E405
Exceeding of the engine temperature
limit
(80°)
-
instantaneously
E406
Exceeding of the internal handle
temperature (80°C) - The tool stops
instantaneously.
E407
Torque
transducer
fault. The measurement is out of
limits
E410
ADC reference value measurement
error
EAP/EDP
The IGBT dissipator temperature is higher than 80°C. Wait for the tool
to cool down. The tool can tighten again when the temperature is lower
than approximately 60°C. Usually this fault is preceded by the E411
fault and only occurs whent the IGBT fan is faulty. Check the fan
functioning.
This error appears after changing the DSP board and after initialising the
EEPROM to download the tool data. The tool does not start, the linearity
table and the engine offsets are not registered in the EEPROM. Tune the
engine from the PDA. This task can only be performed by those who
have attended the maintenance training course.
This error appears for a few seconds when an incorrect access code was
entered. The tool returns automatically to control mode. Re-enter the
programming mode and enter the correct access code.
This could be due to a bug or interferences. Switch off the Bluetooth
radio of the PDA, switch off the tool and re-start.
This could be due to a bug or interferences. Switch off the Bluetooth
radio of the PDA, switch off the tool and re-start.
with
the
The tool does not work. The bluetooth module is faulty, contact our
customer service.
This could be due to a bug or interferences. Switch off the DTU and re-
start.
This could be due to a bug or interferences. Switch off the DTU and re-
start.
This could be due to a bug or interferences. Switch off the DTU and re-
start.
This could be due to a bug or interferences. Switch off the DTU and re-
start.
The power programmed is too large for the tool. For instance you can
reduce the speed. Turn off the tool and turn it on again in order to reset
the fault.
Wait for the tool to cool down. The tool can tighten again when the
The
tool
stops
temperature is lower than 55°C. Usually this fault is preceded by the
E411 fault and only occurs when the engine temperature varies from less
than 60°C to more than 80°C in one cycle.
Wait for the tool cool down. The tool can tighten again when the
temperature is lower than 55°C. Usually this fault is preceded by the
E412 fault. It only occurs when the handle temperature varies from less
than 60°C to more than 80°C in one cycle.
compensation
A torque transducer compensation measurement (offset) is performed at
the beginning of each tightening. This fault means that the compensation
is out of limits by +/- 10% of the nominal load. That shows a torque
transducer zero drift. Make sure the tool is not under stress at the
beginning of the tightening.
DSP reference voltage are faulty. This leads to errors in the measurement
of engine position, temperature, mains voltage, mains current.
Part no
Issue no
Language English
Date
Page
Checking/Actions
6159936431
06
09/2009
24
17 /
Tabla de contenido
loading

Tabla de contenido