Fume Chamber Cleaning; Fume Conduit Cleaning - Cadel CLOE Manual De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 150
If the auger is blocked by a foreign object (for example: nails), and if it needs to be
cleaned, DO NOT remove the hand rejector and DO NOT touch the auger. Please
contact the stove manufacturer or the Technical Assistance service of the stove
manufacturer.
The hand rejector can be removed exclusively by an authorized technician.
12.4

FUME CHAMBER CLEANING

Every 4/8 weeks the fume chamber cleaning must be executed.
For CLOE model: remove top panel and then right panel.
For SQUARE model: loosen the 2 screws that lock front right panel and remove it.
Fig. 46 - Fume chamber
• Unscrew the 2 fume chamber closing zincate panel screw (see Fig. 46 page 85).
• Clean with a vacuum cleaner the ash which has accumulated on the inner (see Fig. 47 page 85).
• After the cleaning the opposite operation is to repeat checking the gasket efficiency and integrity: if
necessary provide for its replacement by an Authorized Technician.
12.5

FUME CONDUIT CLEANING

The exhaust system must be cleaned every month.
CLOE - SQUARE
Fig. 48 - Fume conduit cleaning
Fig. 47 - Fume chamber cleaning
EN
85
Tabla de contenido
loading

Este manual también es adecuado para:

Square

Tabla de contenido