Fume Chamber Cleaning; Fume Conduit Cleaning - Cadel NICE Manual De Instalación, Uso Y Manutención

Ocultar thumbs Ver también para NICE:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 136
If the auger is blocked by a foreign object (for example: nails), and if it needs to be
cleaned, DO NOT remove the hand rejector and DO NOT touch the auger. Please
contact the stove manufacturer or the Technical Assistance service of the stove
manufacturer.
The hand rejector can be removed exclusively by an authorized technician.
12.4

FUME CHAMBER CLEANING

Every 4/8 weeks the fume chamber cleaning must be executed.
Fig. 32 - Fume chamber
• Unscrew the 2 fume chamber closing zincate panel screw which stands on the back of the stove (see
Fig. 32 page 75).
• Clean with a vacuum cleaner the ash which has accumulated on the inner (see Fig. 33 page 75).
• After the cleaning the opposite operation is to repeat checking the gasket efficiency and integrity: if
necessary provide for its replacement by an Authorized Technician.
12.5

FUME CONDUIT CLEANING

The exhaust system must be cleaned every month.
• Remove the inspection lid of the T-union (see Fig. 34 page 75).
NICE - MIRIAM - CRISTAL - LEONORA - PRETTY - DIANA - KRISS - MARY
Fig. 34 - Fume conduit cleaning
Fig. 33 - Fume chamber cleaning