13.2
PROBLEM SOLVING
EN
PROBLEM
The control
display does not
switch on
Pellets do not
reach the
combustion
chamber
92
Before of every Authorized Technician intervention, the same Technician has the duty
to check if the parameters of the mother board correspond to those of the table you
own.
In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized
Technician on order to avoi irreparable damages!
CAUSE
SOLUTION
The stove is
without power
Check if the plug is connected.
supply
Burned board
Replace the protection fuse in the board (4A-250V)
protection fuse
Burned
protection fuse
Replace the protection fuses in the electric socket
in the electric
(3.15A-250V).
socket
Faulty control
Replace the control display.
display
Faulty flat cable
Replace the flat cable.
Faulty electronic
Replace the mother board.
board
Empty hopper
Full the hopper.
Auger blocked
by a foreign
Clean the auger.
object (for
example nails)
The auger
geared motor is
Replace the geared motor.
out of order
Check if on the
display there
Have the stove checked.
is an "ACTIVE
ALARM"
INTERVENTION
CLOE - SQUARE