9.3
GENERAL INSTALLATION WITH PEDESTAL
• Please check that the floor has an adequate load capacity. If the existing one does not satisfy this
requirement, appropriate measure should be provided (for example a plate for distributing the load).
• It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of
300 mm on the sides and 200 mm on the back, to enable an eficient appliance cooling and a good
distribution of heat in the room (see Fig. 14 page 67).
• For safety fire regulations the distances from flammable or sensible to heat objects (sofas, pieces of
furniture, wooden covering, etc...) must be respected, has described in Fig. 14 page 67.
• If there are highly flammable objects (curtains, fitted carpet, etc...), all these distances must be further
increased with 1 meter.
• If the walls are made up of flammable materials, check the safety distances (see Fig. 14 page 67).
• At maximum power check that the wall temperature does not ever exceed 80°C. If it would be necessary
please install a fire resistant plate on the concerned walls.
• In some countries also masonring load-bearing walls are considered flammable.
•
CLOE - SQUARE
LEGEND
Fig. 13 page 66
1
Hole combustion air inlet d.6 cm
2
Exhaust fumes d.8 cm
3
80,3 cm
4
76,5 cm
5
15,8 cm
6
26,8 cm
7
6,5 cm
8
8,5 cm
9
8,2 cm
10
71 cm
11
8,5 cm
12
20,5 cm
13
33 cm
Fig. 14 - General installation with pedestal
LEGEND
Fig. 14 page 67
1
Stove
2
Minimum lateral distance = 300 mm
3
Minimum rear distance = 200 mm
4
Minimum front distance = 1000 mm
EN
67