Cleaning and Caring MagicWatch
10
Cleaning and Caring MagicWatch
Caution!
Never use sharp or hard detergents as they can damage the
sensors.
➤ Clean the sensors with a damp cloth from time to time.
11
Trouble shooting
The unit shows no function
The connecting lines to the reversing lamps do not have any contact or are
interchanged.
The jack of the piezo-speaker is not or is not correctly fitted to the control unit.
The jacks of the sensors are not or are not correctly fitted to the control unit.
➤ Check the jacks and plug them if necessary until they catch.
12
Disposal
➤ Place the packaging material in the appropriate recycling waste bins
wherever possible.
If you wish to finally dispose of the MagicWatch, ask your local
recycling centre or specialist dealer for details about how to do this
in accordance with the applicable disposal regulations.
13
Technical Data
Detection range:
Ultrasonic frequency:
Supply voltage:
Current consumption:
Working temperature:
Loudness of the piezo-speaker:
32
MagicWatch MW150
up to 1.2 m
38.5 kHz
10 – 15 Volts
35 mA (Standby mode)
60 mA (Signal operation)
–20 °C through +70 °C