Single sequential actuation
Place the contact element against the workpiece and
release the trigger.
Fig.24
CAUTION:
Do not place the contact element
against the workpiece with excessive force. Also,
pull the trigger fully and hold it on for 1-2 seconds
after nailing.
contact element re-contacts the workpiece.
Contact actuation
against the workpiece.
Fig.25
Nailing on steel plate
WARNING:
When nailing on the C-shaped
thinner. Otherwise the tool will bounce severely and
WARNING:
Use hardened nails only for steel
plate. Using other purposed nails may cause serious
WARNING:
When nailing, hold the tool so that
it stands upright to the driving surface. Slanted
WARNING:
Do not use the tool for fastening
a corrugated plate or the C-shaped steel directly.
WARNING:
Do not use the tool for nailing on
ceiling or roof.
the table below.
Material thick-
C-shaped steel (B)
ness including
C-shaped steel (A)
9 mm - 22 mm
1.6 mm - 2.3 mm
10 mm - 27 mm
14 mm - 35 mm
15 mm - 40 mm
Fig.26
Nail length (C)
thickness
NOTICE:
Depending on the hardness and
total thickness of all workpiece in combination,
enough fastening may not be obtained. Nailing on
steel plate with excessive depth may extremely
reduce the fastening force.
the nailing depth properly.
NOTICE:
Nailing on the steel plate makes the
driver prematurely worn out and it may cause nail
jamming.
new one.
Nailing on concrete
WARNING:
crete. Using other purposed nails may cause serious
WARNING:
crete or do not fasten directly the steel plate to
the concrete.
WARNING:
it stands upright to the driving surface. Slanted
WARNING:
an object to hang something such as sewer pipe.
the table below.
Wood thick-
ness (A)
-
Fig.27
NOTICE:
Use the tool only for soft concrete
built up not so long before. Driving nails into hard
NOTICE:
When penetrating into concrete
Cutting linked sheet
CAUTION:
from the tool before removing the linked sheet.
12 ENGLISH
Use hardened nails only for con-
Do not nail directly on the con-
When nailing, hold the tool so that
Do not use the tool for fastening
Nail length (B)
Penetration depth
into concrete (C)
Approx. 12 mm
Approx. 13 mm
Approx. 15 mm
Approx. 12 mm
Approx. 15 mm
Always disconnect the air hose
-