18
INSTALLATION / HANDLING
60Hz
COMPRESSOR
Maximum operating pressure
PSIG (bar)
Factory set reload pressure
PSIG (bar)
Flow rate
3
CFM (m
/MIN)
Airend discharge temperature
trip point
Ambient operating
temperature
min.
max.
MOTOR
Motor enclosure
Nominal power
Speed
Frame
Insulation class
COOLING SYSTEM
Air cooled
Cooling air flow
Maximum P in air ducts
Compressed air outlet T
Cooling air outlet T
GENERAL DATA
Residual coolant content
Separator vessel capacity
Coolant capacity
Sound pressure level to
CAGI–PNEUROP
Weight – base mount unit
Weight – 120 gallon Receiver
mounted
Weight – 240 gallon Receiver
mounted
CAUTION
230/460 Dual voltage machines are fitted with a decal to advise the
correct voltage as connected from the factory.
There is a decal fitted to the starter door describing the procedure
to change the connections for the alternative voltage
Rewiring should only be effected by a competent Electrician.
UP6 15–HA
125
150
200
125
150
200
(8.62)
(10.34)
(13.79)
115
140
190
(7.93)
(9.66)
(13.10)
65.4
58
45
(1.84)
(1.64)
(1.28)
ODP
TEFC
15HP
1765 RPM
1770 RPM
256TZ
160 L
3
1770 ft
/min
22_F (12_C)
21_F (12_C)
68 dB(A)
1186 lbs (538 kg)
1510 lbs (685 kg)
1779 lbs (807 kg)
UP6 20–HA
125
150
200
125
150
200
(8.62)
(10.34)
(13.79)
115
140
190
(7.93)
(9.66)
(13.10)
83
75
58
(2.35)
(2.12)
(1.64)
228_F (109_C)
35_F(+2_C )
122_F(+50_C)
ODP
TEFC
20HP
1765 RPM
1770 RPM
284TZ
180 M
F
3
2100 ft
/min
0.5 inWg (12.7mmH
O)
2
24_F (13_C)
26_F (14_C)
3
3ppm (3 mg/m
)
4.5 gallons (17 liters)
3.4 gallons (13 liters)
69 dB(A)
1206 lbs (547 kg)
1530 lbs (694 kg)
1799 lbs (816 kg)
UP6 25–HA
125
150
200
125
150
200
(8.62)
(10.34)
(13.79)
115
140
190
(7.93)
(9.66)
(13.10)
102
92
75
(2.89)
(2.61)
(2.12)
ODP
TEFC
25HP
1765 RPM
1770 RPM
286TZ
180 L
3
2100 ft
/min
19_F (10_C)
29_F (16_C)
69 dB(A)
1292 lbs (586 kg)
1616 lbs (733 kg)
1885 lbs (855 kg)