Installation (Continued)
OIL LEVEL CHECK (See Figure 7)
• Check oil level by removing oil plug.
• With hot oil, the level will be higher than with cold oil.
As a result, oil may escape when the oil plug is opened at
the maximum oil level. If this does happen, close the oil plug
immediately and carefully clean up the oil that has escaped.
NOTE: The oil plug is provided with a safety hole on the side
from which oil or air escapes if there is any residual pressure
in the air end. Wait for one minute after the unit is at standstill
before opening the oil plug.
1. Switch off the system, prevent it from being switched back
on without authorization.
2. Wait for one minute at standstill.
3. Unscrew the oil plug on the filler neck by hand with the air
end depressurized.
4. Check the oil level.
5. If necessary, top off oil of the same oil type and the same
brand up to the maximum level (see Figure 7 and Lubrication
section).
NOTE: The oil filler neck is positioned so that it is not possible to
overfill the system. Excess oil runs out of the filler neck.
6. Screw on the oil plug firmly by hand.
7. Switch on the system.
8. Wipe off and clean up any spilled oil.
START-UP INFORMATION
READ AND UNDERSTAND ALL STEPS BELOW
BEFORE TURNING ON POWER .
1. Check oil level (See Figure 7).
2. If it has been longer than 12 weeks since the compressor has
been operated the air end must be primed with 8 ounces of
oil.
Before resuming operation, the electrical
equipment and all safety-relevant
units must be checked for leaks and proper function. Loose
connections must be refastened and damaged lines must be
replaced.
Screw compressor systems that are switched off, shut down,
or stored for longer than 12 weeks cannot be placed into
operation again until after the following steps have been
carried out:
a. Manually rotate the compact module screw compressor in
the rotation direction several times.
b. With the compressor system stopped, add approximately
8 ounces of oil (same oil type as in the air end) into the
rotor chamber (see Figure 9).
c. Once again, manually rotate the compressor module
compressor stage in the rotation direction several times.
d. Check the oil level in the air end and top off if necessary
(see Maintenance section).
e. Monitor operation of the compressor system for at least
15 minutes, but at least until the steadystate temperature
is reached (continuous operating temperature).
Series CS Rotary Screw Compressors
Upper Intake
Assembly
Nut
Upper Intake
Assembly
Figure 9 - Air End Priming Location
3. Direction of rotation must be checked. Operation of the
air end for more than 2 seconds in the wrong direction will
destroy the screw compressor.
4. Check direction of rotation by quickly bumping the power to
ON and having someone else watch the motor pulley to see
which way it turns. Belt guard should remain installed. Also
check the direction of rotation of the oil cooler fan. The fan
must suck air in from the wire guard side and push air out
through the radiator when turning the correct direction. This
Nut
Filter
Element
Push Valve
Open
Filter
Element