Wiring Diagram
TO SUPPLY
L1
L2
2A
2A
2A
ESTOP
OFF ON
COL
BRANCH CIRCUIT PROTECTION AND DISCONNECT TO BE PROVIDED BY QUALIFIED INSTALLER. INSTALL IN
ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL CODES.
FIELD WIRING TERMINALS SHALL USE MIN 90 DEG C COPPER CONDUCTORS ONLY. TORQUE FIELD WIRING
TERMINAL SCREWS TO 25 IN LBS.
230V 1 PHASE
M
L1
M
L2
M
L3
13
14
HPR 1
HTR 1
TR
TPs
RESET
HTR 2
9
5
HPR 2
HPS
HTR 3
HPR 3
G
Series CS Rotary Screw Compressors
FUSE
5A
OL
T1
OL
T3
OL
LEGEND
COL
COIL OVERLOAD
HTR
HIGH TEMPERATURE RELAY
HPR
HIGH PRESSURE RELAY
TR
TIMER RELAY
TPS
SWITCH, TANK PRESSURE
M
CONTACTOR-MAIN
HPS
SWITCH, HIGH PRESSURE
HOUR
M
METER
TR
5
7
INLET
VALVE
HTR
13
14
HATS
24
26
HPR
R
TR

SINGLE PHASE WIRING DIAGRAM

FAN
W/ AUTO
MOTOR
M1
RESET THERMAL
120V
OVERLOAD
1 PHASE
NEUTRAL
COMP
M2
MOTOR
230V
1 PHASE
POWER ON