PROBLEM
The display scrolls
"CONNECT BATTERY".
Charging a 12V battery,
but the display shows
"CHARGING 6V".
Red LED is solid and the
display scrolls "CHARGE
ABORTED-BAD BATTERY".

18. BEFORE RETURNING FOR REPAIRS

If these solutions do not eliminate the problem, or for more information
about troubleshooting, contact customer service for assistance:
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT SHIP
UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA) number
from Customer Service at Schumacher Electric Corporation.

19. SPECIFICATIONS

Input Voltage ................................................................................120V AC @ 60Hz, 0.91A
Output Voltage .......................................................6V or 12V, with Auto Voltage Detection
Output Current Rating ..........................................................................2A @ 6V; 3A @12V

20. REPLACEMENT PARTS

Battery clamps (quick-connect)..................................................................... 3899002636Z
Ring connectors (quick-connect) ................................................................. 2299002042Z
12V accessory plug (quick-connect) ............................................................. 3899001401Z
POSSIBLE CAUSE
The clamps are not making a
good connection.
The fuse is bad.
Battery may be extremely
discharged.
The battery is bad.
The battery is too large for the
charger.
www.batterychargers.com
or call 1-800-621-5485
Monday-Friday 7:00
• 13 •
Check for poor connection at
battery and frame.
Replace the in-line fuse for
the ring connector or 12V
accessory plug connector.
No problem; the charger
will eventually recognize
battery as 12V and charge
completely.
Disconnect charger from the
AC outlet and then remove
the clamps. Do not continue
to try to charge the battery.
Have the battery checked or
replaced.
You need a charger with a
higher amp rate.