Extension Cords - Delta UniSAW 36-L336 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SHOCK HAZARD. In all cases, make certain
that the receptacle in question is properly grounded. If you
are not sure, have a qualified electrician check the receptacle.
2. Grounded, cord-connected machines intended for use
on a supply circuit having a nominal rating between 150 -
250 volts, inclusive:
If the machine is intended for use on a circuit that has an outlet
that looks like the one illustrated in Fig. A or Fig. B, the machine
will have a grounding plug that looks like the plug illustrated
in Fig. A or Fig. B. Make sure the machine is connected to an
outlet having the same configuration as the plug. No adapter is
available or should be used with this machine. If the machine
must be re-connected for use on a different type of electric
circuit, the re-connection should be made by qualified service
personnel; and after re-connection, the machine should
comply with the National Electric Code and all local codes and
ordinances.
NOTE: The plug for the 3 HP model looks like the plug
illustrated in Fig. A. Make sure the 3 HP machine is connected to
an outlet having the same configuration as the plug.
NOTE: The plug for the 5 HP model looks like the plug
illustrated in Fig. B. Make sure the 5 HP machine is connected to
an outlet having the same configuration as the plug.
3. Permanently connected machines:
If the machine is intended to be permanently connected, all
wiring must be done by a qualified electrician and conform to
the National Electric Code and all local codes and ordinances.
THREE PHASE OPERATION: Three phase machines are not
supplied with a power cord and must be permanently connected
to a building's electrical system. Extension cords can't be used
with a three phase machine.
LVC MAGNETIC MOTOR CONTROL: If you purchased
a machine that has a Low Voltage Magnetic Motor Control
System, refer to its instruction manual for installation guidance.

EXTENSION CORDS

Use proper extension cords. Make sure your
extension cord is in good condition and is a 3-wire extension
cord which has a 3-prong grounding type plug and matching
receptacle which will accept the machine's plug. When using
an extension cord, be sure to use one heavy enough to
carry the current of the machine. An undersized cord will
cause a drop in line voltage, resulting in loss of power
and overheating. Fig. C, shows the correct gauge to use
depending on the cord length. If in doubt, use the next
heavier gauge. The smaller the gauge number, the heavier
the cord.
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE IS
LONGEST OF 3 BLADES
GROUNDED OUTLET BOX
CURRENT
CARRYING
PRONGS
GROUNDING BLADE IS
LONGEST OF 3 BLADES
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere
Length of
Volts
Rating
0-6
240
0-6
240
0-6
240
0-6
240
6-10
240
6-10
240
6-10
240
6-10
240
10-12
240
10-12
240
10-12
240
10-12
240
12-16
240
12-16
240
12-16
240
GREATER THAN 100 FEET NOT RECOMMENDED
16-20
240
16-20
240
GREATER THAN 50 FEET NOT RECOMMENDED
7
FIG. A
FIG. B
Total
Gauge of Extension
Cord in
Cord
Feet
up to 50
18 AWG
50-100
16 AWG
100-200
16 AWG
200-300
14 AWG
up to 50
18 AWG
50-100
16 AWG
100-200
14 AWG
200-300
12 AWG
up to 50
16 AWG
50-100
16 AWG
100-200
14 AWG
200-300
12 AWG
up to 50
14 AWG
50-100
12 AWG
up to 50
10 AWG
Fig. C