5.2.1

Manual mode

The operator must set appropriate values for the wire feed speed and welding
voltage.
5.2.2

QSet mode

A
E
B
D
C
G
In QSet mode the appropriate welding voltage is automatically set by the power
source. QSet monitors the welding arc and continuously adjusts the voltage to
maintain the optimal setting.
bc22a
F
I
H
- 16 -
A - Welding voltage
B - Welding current
C - Wire feed speed
F - Voltage setting knob
G - Manual/QSet mode button
H - Inductance setting button
I - Wire feed speed setting
knob
A - Welding voltage
B - Welding current
C - Wire feed speed
D - Plate thickness
E - QSet value
F - QSet value setting knob
G - Manuel/QSet mode button
H - Material selection/
Inductance setting button
I - Plate thickness setting knob