ow to install your oven
Electrical connections
220-240 V single phase
alternating current
supply
Socket
2 -pin with earth
Before connecting your oven, make sure you are using the
correct size cable.
Use a 16-amp fuse.
The electrical connections are made before the oven is installed in its housing.
• The oven must be connected using an approved 3-core cable (live, neutral and
earth) with 1.5 mm square conductors. This should be connected via a 3- pin-
socket (live, neutral, and earth to the main supply which should be should be a
220-240V, alternating single-phase current. If the oven is not connected using a
plug and socket, it must be connected to a multi-pole switch with a minimum gap
of 3 mm between contacts. The earth wire (green and yellow) should be connec-
ted to the terminal marked with the earth symbol
earth in the switch.
• Where the oven is connected using a separate plug and socket this must be ac-
cessible after the oven has been installed.
• The neutral wire (blue) of the oven must be connected to the neutral in the main
supply.
16:55
Page 35
Fused 16A or differential circuit breaker
Connecting
cable approx
1.50 m. long
Electricity meter (mains)
(20A, single-phase
220-240 V alternating
current 50 Hz)