cecotec FORCECLIMA 14600 SOUNDLESS HEATING Manual De Instrucciones página 32

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
ENGLISH
5.
Increase/decrease
6.
Modes
7.
Fan speed
8.
Unit switch:
NOTE:
The graphics in this manual are schematic representations and may not exactly match the
product.
2. BEFORE USE
-
This appliance is packaged in a way as to protect it during transport. Take the appliance
out of its box and remove all packaging materials. You can keep the original box and other
packaging elements in a safe place. This will help you prevent product damage when
transporting it in the future. In case the original packaging is disposed of, make sure all
packaging materials are recycled accordingly.
-
Make sure all parts and components are included and in good conditions. If there is any
piece missing or in bad conditions, contact the official Cecotec Technical Support Service
immediately.
Box contents
-
ForceClima 14600 SoundLess Heating portable air conditioner
-
Window kit
-
Remote control
-
Instruction manual
3. PRODUCT INSTALLATION
NOTE:
-
Leave a minimum of 50 cm distance to walls and other objects. Fig. 6
-
Do not install and use the air conditioning in the bathroom or other humid environments.
-
Before using the portable air conditioner, keep it upright for at least two hours. When
moving the appliance from one place to another, always do it with the device in an upright
position and leaving it in a flat surface.
-
The air outlet pipe should be 28-150 cm long, this length is based on the specifications of
the air conditioner. Do not use extendible pipes or replace the pipe with a different one, as
this may cause the product to malfunction. The exhaust pipe must be clear of obstructions;
otherwise it may cause overheating.
62
FORCECLIMA 14600 SOUNDLESS HEATING
Installing of the air outlet pipe. Fig. 7
1.
Stretch the air outlet pipe.
2.
Insert the pipe into the air outlet.
3.
Turn the end counterclockwise to fix it to the air conditioner body.
NOTE:
-
The flat end of the exhaust pipe joints must be snapped into place.
-
The air outlet pipe must not be twisted or bent more than 45°. Keep the air outlet pipe free
of obstructions.
Installing the window sealing plate
You can install the window sealing plate either vertically (Fig. 8) or horizontally (Fig. 9). Adjust
the size of the opening so that the sealing plate remains fixed in it.
The following checks must be applied to installations using flammable refrigerants:
-
The load size is in accordance with the size of the room where refrigerant-containing parts
are installed.
-
Ventilation machinery and outlets can be properly operated and are unobstructed.
-
If an indirect cooling circuit is used, the secondary circuit must be checked for refrigerant
presence.
-
Equipment marking remains visible and legible. Illegible markings and symbols should be
corrected.
-
The components or refrigerant piping are installed in a position where they are not
susceptible to exposure to any substance that may corrode the refrigerant-containing
components, unless the components are made of materials that are inherently resistant
to corrosion or are properly protected against it.
4. OPERATION
The following functions can be activated from the control panel or from the remote control.
On/Off
(Remote control)
When the device is turned on, it will beep and enter standby mode. Touch the power key to turn
the device on and off.
Modo
(Remote control)
Press the mode icon to switch between cooling, fan, and dehumidification modes.
Note:
when the appliance is running in cooling and dehumidification mode, the condensate
drainage will be done through the upper condensate outlet. When the device is running in
ENGLISH
FORCECLIMA 14600 SOUNDLESS HEATING
63