All manuals and user guides at all-guides.com
LAMP REPLACEMENT: The Safety Light uses a 6.3 volt 250mA
fuse type lamp which has an average life of 50 hours. If the
Safety Light does not operate with a fresh alkaline battery, replace
the lamp. To replace the lamp, remove the alarm from trim ring
by following the ALARM REMOVAL instructions at the beginning
of this section. Open the battery door and remove both batteries
from the unit. Grip the lamp holder with your thumb and finger
(see Figure 10) and pull out the lamp holder assembly (see Figure
10A). Slide the old lamp out of the lamp holder and replace it
with a new lamp (see Figure 10B). Replace with the correct lamp
type; Vanco #FTB 6, available at most radio/tv repair stores.
FIGURE 10
FIGURE 10A
FIGURE 10B
Reinstall the lamp holder. It will snap easily into the base. Put
working batteries back in the alarm and remount the alarm on its
mounting trim ring.
CAUTION! USE ONLY LAMP SPECIFIED. USE OF A DIFFERENT
LAMP MAY HAVE A DETRIMENTAL EFFECT ON THE SMOKE
ALARM OR THE SAFETY LIGHT OPERATION.
NOTE: IF AFTER BATTERY OR LAMP REPLACEMENT THE
ALARM CONTINUES TO CHIRP, PUSH THE TEST BUTTON. THE
"HUSH" FEATURE (IF EQUIPPED) MAY HAVE BEEN ACTIVATED
ACCIDENTLY WHILE CHANGING THE BATTERIES AND PUSH-
ING THE TEST BUTTON WILL END THE HUSH CYCLE.
CLEANING YOUR ALARM
YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR.
To clean your alarm, remove it from the mounting bracket as out-
lined in the beginning of this section. You can clean the interior
of your alarm (sensing chamber) by using compressed air or a vac-
uum cleaner hose and blowing or vacuuming through the open-
ings around the perimeter of the alarm. The outside of the alarm
can be wiped with a damp cloth. After cleaning, reinstall your
alarm and test your alarm by using the test button. If cleaning