Página 1
For model: 0918 0918 Smoke Alarm User’s Guide 9 Volt Battery Operated Smoke Alarm with Battery Powered Safety Light and “HUSH” Control (if equipped) to temporarily silence nuisance alarms. Thank you for purchasing this smoke alarm. It is an important part of your family’s home safety plan.
Página 2
This alarm detects products of combustion using the ionization technique. It contains 0.9 microcurie of Americium 241, a radioac- tive material (see Section 9). Distributed under U.S. NRC License No. 32-23858-01E. Manufactured in compliance with U.S. NRC safety criteria in 10 CFR 32.27. The purchaser is exempt from any regulatory requirements.
Página 3
• Locate an alarm in every room where electrical appliances are operated (i.e. portable heaters or humidifiers). • Locate an alarm in every room where someone sleeps with the door closed. The closed door may prevent an alarm not locat- ed in that room from waking the sleeper.
• Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 30 feet (9.1 m) long. • Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 3 ft (0.9m)of the highest point (measured horizontally). NFPA 72 states: “Smoke alarms in rooms with ceiling slopes greater than 1 foot in 8 feet (.3m in 2.4m) horizontally shall be located on the high side of the room.”...
• In very humid areas. Moisture or steam can cause nuisance alarms. • In insect-infested areas. • Smoke alarms should not be installed within 3 ft (.9m) of the fol- lowing: the door to a kitchen, the door to a bathroom containing a tub or shower, forced air supply ducts used for heating or cool- ing, ceiling or whole house ventilating fans, or other high air flow areas.
Página 6
1. Remove the mounting plate from the back of the alarm by holding the mounting plate and twisting the alarm in the direc- tion indicated by the “OFF” arrow on the alarm cover. 2. To insure aesthetic alignment of the alarm with the hallway or wall, the “A”...
Página 7
TIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS. SAFETY LIGHT: The model 0918 has a Safety Light feature. When the smoke alarm ionization chamber senses smoke, the 85 db horn will sound and the Safety Light will illuminate until the sens- ing chamber is cleared of smoke particles.
(non-recirculating type) will also help remove these combustible products from the kitchen. (If equipped) Model 0918 has a “HUSH” button that is extremely useful in a kitchen area or other areas prone to nuisance alarms.
Página 9
BATTERIES, THE BATTERY DOOR WILL NOT CLOSE AND THE ALARM WILL NOT ATTACH TO THE TRIM RING. The Model 0918 Smoke Alarm uses two (2) 9 volt batteries. This smoke alarm is powered by a 9V lithium battery (carbon zinc and alkaline batteries may also be used).
Carbon-zinc type EVEREADY 216 OR 1222; GOLD PEAK 1604P OR 1604S Alkaline type ENERGIZER 522; DURACELL MN1604, MX1604; GOLD PEAK 1604A; PANASONIC 6AM6, 6AM-6, 6AM-6PI, 6AM6X, AND 6LR61 (GA) Lithium type ULTRALIFE U9VL-J The SAFETY LIGHT portion is powered by one (1) 9V alkaline bat- tery.
Página 11
Replace with the correct lamp type; Vanco #FTB 6, available at most radio/tv repair stores. The lamp is also available from KIDDE Safety, 1016 Corporate Park Dr., Mebane, NC 27302. Send $1.50 (check or money order) and request a 0918 replacement lamp.
Página 12
Photoelectric sensing alarms may detect visible fire particles (associated with slow smoldering fires) sooner than ionization alarms. Home fires develop in different ways and are often unpredictable. For maximum protection, Kidde recom- mends that both Ionization and Photoelectric alarms be installed.
Página 13
• Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire. • Determine a place outside your home where you all can meet if a fire occurs. • Familiarize everyone with the sound of the smoke alarm and train them to leave your home when they hear it.
Página 14
a) smoking in bed b) leaving children home alone c) cleaning with flammable liquids, such as gasoline 9. NRC INFORMATION Ionization type smoke alarms use a very small amount of a radioactive element in the sensing chamber to enable detection of visible and invisible combustion products.
If after reviewing this manual you feel that your smoke alarm is defective in any way, do not tamper with the unit. Return it for servicing to: KIDDE Safety, 1016 Corporate Park Dr., Mebane, NC 27302. 800-880-6788 (See Warranty for in-warranty returns).
Página 16
(but not the battery) will be free from defects in material and workmanship or design under normal use and service for a period of five years from the date of purchase. The obligation of KIDDE Safety under this warranty is limited to repairing or replacing the smoke alarm...
Para el modelo: 0918 0918 Guía del usuario de alarmas contra humo Alarma contra humo a batería de 9 voltios con luz de seguridad alimentada por baterías y control de silenciador (si se incluye) para silenciar temporalmente alarmas molestas. Gracias por comprar esta alarma contra humo, es parte impor- tante del plan de seguridad de su hogar.
Esta alarma detecta productos de combustión usando la técnica de ionización. Contiene 0.9 microcurios de americio 241, que es un material radiactivo (consulte la Sección 9). Se distribuye bajo licencia de NRC de EE.UU., Nº 32-23858-01E. Fabricada en conformi- dad con los criterios de seguridad de NRC de EE.UU. en 10 CFR 32.27. El comprador está...
MEJOR NUNCA AQUÍ AQUÍ • Para la instalación de alarmas en casas rodantes, seleccione cuidadosamente los MÁXIMO 12 pulg. lugares de instalación para evitar que se formen barreras térmicas en el cielo raso. (30,5 cm.) Para obtener más detalles, consulte INSTALACIÓN EN CASAS RODANTES a contin- uación.
ADVERTENCIA: PRUEBE EL FUNCIONAMIENTO DE LA ALARMA DESPUÉS DE QUE SU VEHÍCULO DE RECREACIÓN O CASA RODANTE HAYA ESTADO GUARDADO, ANTES DE CADA VIAJE Y COMO MÍNIMO UNA VEZ A LA SEMANA CUANDO ESTÉ EN USO. 2. UBICACIONES QUE ES NECESARIO EVITAR •...
3. Después de seleccionar la ubicación adecuada para la alarma contra humo, como se describe en la Sección 1, conecte la placa de montaje al cielo raso como se muestra en la Figura 4. Para instalar la alarma en la pared, consulte la Figura 5. Coloque la placa de montaje en la pared.
El modelo 0918 (si se incluye) tiene un botón de silenciador que es muy útil en el área de la cocina o en otras áreas propensas a producir alarmas molestas. Para obtener más información, consulte la Sección 4, FUNCIONAMIENTO Y PRUEBA.
SE CONECTARÁ AL ANILLO DE AJUSTE. La alarma contra humo modelo 0918 usa dos (2) baterías de 9 voltios. La alarma contra humo usa una batería de carbón y cinc de 9 V (también se pueden usar baterías de litio y alcalinas).
La bombilla también se puede conseguir en KIDDE Safety, 1394 South Third Street, Mebane, NC 27302. Envíe $1.50 (cheque u orden de pago) y solicite una bombilla de repuesto para el modelo 0918.
(asociadas a incendios de expansión lenta) más rápido que las alarmas de ionización. Los incendios en las casas se pueden producir de diferentes formas y, con frecuencia, son impredecibles. Kidde recomienda que, para una máxima protección, se instalen alarmas de ionización y fotoeléctricas.
• Elabore un plano en que estén señaladas todas las puertas y ventanas, y al menos dos (2) rutas de escape desde cada habitación. Podrían ser necesarias una escala de cuer- das o de cadena en las ventanas del segundo piso. •...
12. SERVICIO Y GARANTÍA Si después de revisar este manual aún cree que su alarma contra humo está defectuosa, no la manipule. Devuélvala para su reparación a: KIDDE Safety, 1016 Corporate Park Drive, Mebane, NC 27302. 800-880-6788 (consulte la sección Garantía para obtener...
La obligación de KIDDE Safety de acuerdo con esta garantía está limitada a la reparación o reemplazo, sin costos para el cliente, de la alarma contra humo o de cualquier pieza que esté...