4-wire connection instructions
Before wiring the range review the suggested power
source location drawing in Fig. B. If connecting to a 4-Wire
electrical system (new branch-circuit or mobile home
requires 4-Wire connection):
Power cord instructions
1.
Follow the manufacturer's installation instructions
supplied with the strain relief and install (See Fig. 28).
2.
Insert the end connectors for Line 1, Line 2 and
Neutral and tighten securely to the terminal block.
IMPORTANT NOTE:
DO NOT LOOSEN
the factory
installed nut connections which secure the range
wiring to the terminal block. Electrical failure or loss
of electrical connection may occur if these 3 nuts are
loosened or removed.
3.
You must disconnect the ground strap.
Remove the
factory installed ground screw and plate to release the
copper ground strap from the frame of the appliance.
Cut and discard the copper ground strap and plate.
KEEP the ground screw.
4.
Connect the ground wire (Green) lead with the eyelet
to the frame of the appliance with the ground screw
using the same hole in the frame where the ground
screw was originally installed (See Fig. 29).
5.
Make sure all screws are tightened securely and
replace the rear access cover (See Fig. 25).
4-Wire Connection
3 Factory installed connections
(DO NOT LOOSEN)
Connect
neutral
(white or
center) here
Terminal
ve
o g g
"
a
block
Connect
line 7
here
Connect
Cut ground
line 2
strap. Discard
here
ground strap
& ground plate
Connect green
insulated copper
ground wire with
ground screw here
NOTES:
install strain-relief
bushing. Center or white
wire must always be
attached to the center
terminal on block
Fig. 29
3-wire connection instructions
(for existing installations ONLY)
Power Cord Instructions
1.
Follow the manufacturer's installation instructions
supplied with the strain relief and install (See Fig. 28).
2.
Insert the end connectors for Line 1, Line 2 and
Neutral and tighten securely to the terminal block (See
Fig. 30).
IMPORTANT NOTE:
DO NOT LOOSEN the factory
installed nut connections which secure the range
wiring to the terminal block. Electrical failure or loss
of electrical connection may occur if these 3 nuts are
loosened or removed.
Make sure all connections are tightened securely and
replace the rear access cover (See Fig. 25).
3-Wire Connection
3 Factory installed connections
Connect
hornet
(DO NOT LOOSEN)
neutral
here
(white or
center) here
Terminal
@4
1
ig
ory)
1
bes
Feng
hos
viok
POE
(CO) (Oe
on
OE
tssenitia
| Chenega
39)
Ground strap
S
a2
2}
Connect
Q
AS
o
line 2
#
2 Bs]
=
here
2\| ®|
2\>
|=
a
B\C
rit
Ground screw
m
& ground plate
NOTES:
Install strain-relief
bushing. Center or white
wire must always be
attached to the center
terminal on block
Fig. 30
3-Wire Connections ONLY - Grounding
Instructions
A ground strap is installed on this range which connects
the center terminal of the terminal block (neutral) to the
range chassis. The ground strap is connected to the range
by the center, lowest screw (See Fig. 30). The ground
strap must not be removed unless national or local codes
do not permit use of ground strap.
NOTE:
lf the ground strap is removed for any reason, a
separate ground wire must be connected to the separate
ground screw attached to the range chassis and to an
adequate ground source.