Kenmore 79075353314 Instrucciones De Instalación página 6

Idiomas disponibles

Idiomas disponibles

3.
Drill Pilot Holes & Fasten Bracket - Drill 1/8" pilot
hole where screws are to be located (Fig. 21). If
bracket is to be mounted to the wail, drill pilot hole at
an approximate 20° downward angle. If bracket is to
be mounted to masonry or ceramic floors, drill 3/16"
pilot hole 1-3/4" deep. The screws provided may be
used in wood or concrete material.
Use 5/16" nut-
driver or flat head screwdriver to secure the bracket in
place.
Fig 21
4.
Level & Position Range - Level range by adjusting
the (4) leveling legs with a wrench. Note: A minimum
clearance of 1/8" is required between bottom of range
and leveling legs to allow room for bracket. Slide range
back into position (Fig. 22). Remove lower panel or
storage drawer to visually check that rear leveling leg
is inserted into and fully secured by the bracket. For
models with a warmer drawer or broiler compartment,
grasp the top rear edge of the range and carefully
attempt to tilt it forward.
TN"
Range Side
~
Fig 22
5.
Use a level to check your adjustments (Fig. 23).
Fig 23
Electrical connection requirements
3 and 4 - Wire electrical wall receptacle types and
recommended
mounting orientation on wall
Required for new and remodeled
G
installations
<
¥(|
a
4-Wire Wall receptacle (14-50R)
Allowed for existing installations
3 Wire Wall
receptacle (10-50R)
Fig. 24
This appliance must be properly installed and grounded
by a qualified technician in accordance with the National
Electrical Code ANSI/NFPA No. 70 -- latest edition -- and
local electrical code requirements.
This appliance may be connected by means of permanent
"Hard Wiring" or "Power Supply Cord Kit."
When hard wiring, do not leave excess wire in range
compartment. Excess wire in the range compartment may
not allow the access cover to be replaced properly, and
could create a potential electrical hazard if wires become
pinched. Connect only as instructed under "WIRING
INSTRUCTIONS?' in Step B of the Installation Steps. When
using flexible conduit or range cable use flex connector or
range cable strain relief (See Fig. 27 on page 7).
NOTE:
Only use copper wire in connection to terminal
block.
MODELS REQUIRING POWER SUPPLY CORD KIT
RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IF
AN INCORRECT SIZE RANGE CORD KIT IS USED, THE
INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED
OR STRAIN RELIEF BRACKET IS DISCARDED.
This appliance may be connected by means of a power
supply cord. Only a power supply cord kit rated at 125/250
volts minimum, and marked for use with ranges shall
be used. See chart (Fig. 28) for cord kit ampere rating
information. Cord must have either four (4) or three (3)
conductors (See Fig. 24). Terminals on end of wires
must be either closed loop or open-end spade lugs with
upturned ends. Cord must have strain relief clamp. See
Step B
in Installation Steps for 4 or 3 - Wire connections.