Carefully slide range into cabinet
opening.
Carefully slide range into cabinet opening while inserting
rear leveling leg into and FULLY ENGAGING THE ANTI-
TIP BRACKET (See Fig. 22 on page 6). Make sure that
the flexible appliance conduit and the power cord folds into
the remaining open floor area behind the range warmer
or storage drawer. Make sure that the flexible appliance
conduit does not become pinched or kinked. Pre-shape the
flexible appliance conduit and power cord if necessary to
insure that the range slides into cabinet opening properly.
Be sure to check level of the range by placing a level
horizontally on an oven rack (See Fig. 23 on page 6).
moyen
Surface burner heads, cap & grates
It is very important to make sure that all of the surface
burner heads, surface burner caps and surface burner
grates are installed correctly.
Your appliance was shipped with the burner heads and
burner caps assembled in the correct locations (See
Fig. 34).
Should you need to re-install the burner caps please refer
to the Use & Care guide for more information.
REMEMBER—DONOTALLOW SPILLS, FOOD, CLEANING
AGENTS ORANY OTHER MATERIAL TO ENTER THE GAS
ORIFICE HOLDER OPENING.
Always keep the Burner Caps and Burner Heads in place
whenever the surface burners are in use.
1 4 .
5,000 BTU Simmer Burner.
2.
10,000 BTU Bridge Burner.
3.
9,500 BTU Power Burner.
4.
12,000 or
14,200 BTU Power Burner.
5
Fig. 34
18,000 BTU Double Burner (some models).
Check electric ignition of surface burners
Operation of electric igniters should be checked after range
and supply line connectors have been carefully checked for
leaks and range has been connected to electric power.
a.
To check for proper ignition, push in and turn a surface
burner knob counterclockwise to the LITE position
(see Fig. 35). You will hear the igniter sparking.
b.
The surface burner should ignite when gas is available
to the burner. Purge air from supply lines by leaving
knob in the LITE position until burner ignites. Each
burner should light within four (4) seconds in normal
operation after air has been purged from supply lines.
c.
Visually check that burner has a flame. Once the
burner ignites, the control knob should be turned out of
the LITE position.
d.
Try each surface control knob separately until all
surface burners have been checked. Each burner
location is equipped with a separate electrode.
Fig. 35