2
Electric supply connections
•
Cut the electricity supply before any work inside the appliance (risk of electric shock). The removal of the power
supply has to be such that you can always check from any of the points to which you have access that the power
supply remains removed. If this is not possible, you should provide a disconnection with a locking system.
•
Only a qualified and experienced technician is authorised to carry out cabling work within the appliance or to
replace the power cord.
•
Make sure that the terminal screws are fully tightened (risk of fire). Incorrectly tightened terminal screws will cancel
the warranty.
•
Do not disconnect the electricity supply when the appliance is running. If the electric power supply is interrupted,
wait a minute before restoring the power.
Connect the unit to the power supply and options
Open the top panel
with a screwdriver (4 screws) to access the electrical terminal block.
Insert the power supply cable into one of the cable gland
Inside the appliance, fix the power supply cable by threading it through the cable clamp
Connect the power supply cable to the terminal block inside the appliance as following.
Connect options
Connect to
(filtration pump,
power supply
power supply relay).
Terminal block for single phase power supply
Cable wiring and protection
Electricity
Max.
Model
supply
current
MD3
MD4
MD5
220 - 240 V
MD6
1 phase
50-60 Hz
MD8
MD9
MD12
TD8
380 - 400 V
TD9
3 phase
50-60 Hz
TD12
*Cable cross section suitable for max. length 20 meters.
on the rear part of the appliance.
Connect
to power
supply
Terminal block for tri-phase power supply
Cable diameter*
8
9
RO2V 3x2,5 mm
13
16
19
RO2V 3x4 mm
²
20
30
RO2V 3x6 mm
²
21
RO2V 5x2,5 mm
24
30
RO2V 5x4 mm
²
.
L: Live
N: Neutral
: Earth
Connect options
(filtration pump,
power supply relay)
Thermal magnetic protection
²
²
Heating priority connection
P2 P1
1 -
2: Power for the filtration
pump power contactor evaporator
: filtration timer
: power contactor (two-pole contac-
tor) for filtration system pump motor
: separate cable for the "heating
priority" function (not supplied)
: heat pump terminal board
: fuse
230V/dry contact relay (not
:
included)
16 A
16 A
16 A
20 A
20 A
25 A
32 A
25 A
25 A
32 A
❶
Installation
1
14
2
13
5