a brand of Hugo Lahme GmbH
Assembly of functional unit and panel
1. Lead the pre-assembled supply cable for the power supply, which is within the recess, outwards using the cable screw.
ATTENTION: Do not leave more than a 1 meter cable in the recess. This could damage moving parts!
Secure the cable in the clamp. Tighten the nut of the cable screw to form a seal.
2. Lubricate the O-rings at the functional unit
for air and water supply.
3. Insert the Total-Jet massage system's functional unit into the recess. Ensure that the supply cable in the recess is 1 meters long.
The cable must not impede the operating movement of the massage system Total-Jet!
CAUTION: As soon as the O-ring glides into the seat to form the seal,
the functional unit could quickly slip into the recess.
Danger of being crushed!
4. The complete assembly kit is bolted to the 3 M6 screws
with the 3 M6 screw nuts supplied.
Tightening torque: 2 Nm max.
Put on the panel and attach to the recess firmly with the
4 M6 screws supplied.
Stand 04/2023
O-Ring
O Ring
10
O Ring
O-Ring
Art.-Nr.: 578913