Issues
Smell of gas
The pilot light does not
light up
The pilot light goes off .
The fl ame is yellow.
Burner control knob is
stiff .
3329590_ut_GB_rev.2
FAULTS
TROUBLESHOOTING
agents or headquarters, which can be found
in the contacts section of the website www.
angelopo.com.
Causes
Occasional leak because
fl ame has gone off .
The spark ignition devices
are not working.
Air in pipelines due to long
period of downtime.
The thermocouple has not
heated up enough.
The burner is dirty.
Gas control valve fault.
NOTE:
For any need, please contact Angelo Po's
Close the gas supply tap and
ventilate the room.
Check that the ignition devices are
in good working order. Light by
hand with a naked light.
NOTE: Contact the af-
ter-sales service.
Make more attempts
to light the fl ame.
Make more attempts
to light the fl ame.
Clean the burner
NOTE: Contact the af-
ter-sales service.