The power tool should be cleaned regularly, often
and thoroughly through all front and rear air vents
using a vacuum cleaner or by blowing in dry air.
Prior to this operation, separate the power tool from
the power source and wear protective glasses and
a suitable dust mask. Ensure appropriate suction is
available when blowing out vents.
8. Troubleshooting
The electronic signal display (13) flashes
and the machine does not start.
The battery pack is empty; the temperature is
too high or the restart protection has triggered.
Switch the machine off and back on again.
The machine will not start if the battery pack is
inserted while the machine is on.
The electronic signal display (13) is
permanently on.
There has been an overload while working,
therefore the performance may be reduced
temporarily. Reduce working pressure.
Electronic safety shutdown: the machine has
SHUT DOWN by itself. If the slew rate of the
current is too high (for example, if the machine
suddenly seizes or kickback occurs), the machine
switches off. Switch off the machine. Switch it on
again and continue to work as normal. Try to
prevent the machine from seizing. See chapter 3.2.
9. Accessories
Use only original Metabo or CAS (Cordless Alliance
System) battery packs and accessories.
Use only accessories that fulfil the requirements
and specifications listed in these operating
instructions.
Fit accessories securely. If the machine is operated
in a holder: secure the machine well. Loss of control
can cause personal injury.
A Collet chucks, including nut (hexagon)
Ø 3 mm = 631947000
Ø 1/8"
= 631948000
Ø 6 mm = 631945000
Ø 1/4"
= 631949000
Ø 8 mm = 631946000
B Collet chucks, including nut (double flat)
Ø 6 mm = 630820000
Ø 1/4"
= 630821000
Ø 8 mm = 630833000
C Clamping frame 627354000 for clamping
during work with flexible shafts (tighten
clamping screw), including:
D Clamping bracket 627107000 for safe securing to
the work bench (tighten clamping screw).
E Clamping frame: 628329000
F Flexible shafts
G Auxiliary handle: 631052000
H Dust protection filter (as a replacement):
630439000
I Chargers: ASC 55, ASC 145, etc.
J Battery packs:
Order no.: 625027000 4.0 Ah (Li-Power)
Order no.: 625368000 5.5 Ah (LiHD)
10
Order no.: 625369000 8.0 Ah (LiHD)
Order no.: 625549000 10.0 Ah (LiHD)
etc.
See www.metabo.com or the catalogue for a
complete range of accessories.
10. Repairs
Repairs to electrical tools must only be carried
out by qualified electricians!
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. For
addresses see www.metabo.com.
You can download a list of spare parts from
www.metabo.com.
11. Environmental Protection
The sanding dust generated may contain
hazardous materials: do not dispose of dust with
household waste, but at a special collection point
for hazardous waste.
Packaging materials must be disposed of according
to their labelling in accordance with municipal
guidelines. Further information can be found at
www.metabo.com in the "Service" section.
Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
Battery packs must not be disposed of with regular
waste! Please return faulty or used battery packs to
your Metabo dealer!
Do not throw battery packs into water.
12. Technical Specifications
Explanatory notes regarding the specifications on
page 3. Subject to change in accordance with
technical progress.
S
= spindle lock for easy tool changes
U
= Voltage of battery pack
n
= No-load speed (maximum speed)
n
*
= No-load speed (adjustable)
V
D
=Maximum accessory diameter
max, grinding
(grinding)
D
=Maximum accessory diameter
max, polishing
(polishing)
T
= max. thickness of bonded grinding discs
max
d
= collet bore of the collet chuck
m
= Weight with smallest battery pack
L
= maximum insertion depth
max
Permitted ambient temperature during operation:
-20 °C (-4°F) to 50 °C (120°F) (limited performance
with temperatures below 0 °C (32°F)). Permitted
ambient temperature for storage: 0 °C to 30 °C.
The technical specifications quoted are subject to
tolerances (in compliance with relevant valid
standards).
Emission values
These values make it possible to assess the
emissions from the power tool and to compare
different power tools. The actual load may be higher