Kenmore 125.16642900 Guía De Uso Y Cuidado página 20

Idiomas disponibles

Idiomas disponibles

TRANSPORTING
AND STORAGE:
Never move a grill when it is hot or when objects
are
on the cooking surfaces.
Make sure that cylinder valve is shut off. After moving
the grill check that all gas connections
are free of leaks. Refer to instructions
for Leak
Testing.
DO NOT store a spare LP gas cylinder (filled or
empty) under or near the grill.
Never store flammable
liquids or spray canisters
under or near the grill.
DO NOT extinguish
grease fires using water.
If the outdoor cooking gas appliance
is not in use, the
gas must be turned off at the supply cylinder.
Storage
of an outdoor cooking
gas appliance
indoors
is permissible
only if the cylinder is
disconnected
and removed
from the outdoor cooking
gas appliance.
Cylinders
must be stored outdoors
out of reach of
children and must not be stored in a
building, garage or any other enclosed
area.
When removing
the grill from storage,
spider webs or
other debris may be blocking the burner. See "Burner
Assembly/Maintenance"
under Proper Care and
Maintenance.
PROBLEM
Burner
will
not light
Fire at
control
knob
Yellow
Flames
at burner
Flame blows
out on "LOW"
Burner
does
not get hot
enough
Grill is
too hot
CAUSE
1. Check LP cylinder fuel level.
2. Bad electrode spark. Check to see if
the grill will match light. Electrode or
collector may need adjustment.
3. Burner may not be properly seated.
4. Burner may be obstructed.
5.The cylinder valve may be closed.
6. Regulator is not properly seated on
cylinder valve.
1. Burner holes may be obstructed.
See section on "After Use Safety
and Maintenance".
2. Burner is improperly seated on
control valve.
3. Gas connections
may be loose.
Leak Check and tighten all
connections.
1. Burner is obstructed.
See Burner
Assembly/Maintenance
in After Use
Safety and Maintenance section.
1. Burner holes may be obstructed.
See Burner Assembly/Maintenance
in After Use Safety and Maintenance
section.
2. Grill is not sufficiently preheated.
3. Burner is improperly seated on
control valve.
1. Flow control device has been
activated in regulator. See
Regulator Resetting Procedure
under Connecting
LP Cylinder
and Hose/Regulator
to Grill.
1. Excess grease build-up causing
grease fires.
2. Damaged or faulty regulator. Replace
with identical replacement
parts.
3. Cook on a lower temperature setting.
To order replacement
parts,
call 1-800-848-8915