tau DC20 Guía Para La Instalación página 26

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
OPENING PRIORITY
10
(INTERLOCK)
11
INSIDE SENSOR TEST
12
OUTSIDE SENSOR TEST
Dip switch SW2
1
2
3
DOORS
4
DIRECTION
If the automatic door has a single leaf opening to the right, it is necessary to reverse
the controls of the dip switch 4 as follows: ON: opening towards the left - OFF: opening
towards the right (standard)
5
6
BATTERY CHARGER KEY
Key:
LED steady on;
GREEN LED – battery charger
status
off
flashing every 2 seconds
continuous flashing
flashing every 4 seconds
steadily lit
RED LED – fault diagnostics
off
steadily lit
continuous flashing
flashing every 2 seconds
With ACTIVE INTERLOCK function. Set in ON on the control board
ON
that must have LOW priority.
With ACTIVE INTERLOCK function. Set in OFF on the control board
OFF
that must have HIGH priority.
Enables internal sensor test – the test is performed on the input
ON
- and + TEST of the connector J19.
OFF
Disables the test on the input of the connector J19.
Enables external sensor test – the test is performed on the input
ON
- and + TEST of the connector J20.
OFF
Disables the test on the input of the connector J20.
ON
OFF
Keep the Dip switch in OFF
ON
OFF
Keep the Dip switch in OFF
ON
OFF
Keep the Dip switch in OFF
ON
Opening towards the right
OFF
Opening towards the left
ON
OFF
Keep the Dip switch in OFF
ON
OFF
Keep the Dip switch in OFF
LED flashing;
battery charger off;
initial slow charge;
under fast charge;
in backup;
battery charged;
everything OK;
FAULTY battery (cell voltage < than the minimum or .....)
short circuit
battery not connected
26