tau DC20 Guía Para La Instalación página 20

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
"APERTURA INVERNALE"
(WINTER OPENING)
"APERTURA FARMACIA"
(PHARMACY OPENING)
CONNECTIONS TO TERMINAL BOARD
-
CONNECTOR J2
Terminals
Input/Output
29
NEGATIVE T-LINETD POWER
30
B T-LINETD SIGNAL
31
A T-LINETD SIGNAL
32
POSITIVE T-LINETD POWER
N.B .: Look the D-MNL0TLINETD manual for its operation
CONNECTOR J3 -
CONNECTOR J4 -
CONNECTOR J5 -
CONNECTOR J6 -
CONNECTOR J7 -
CONNECTOR J8 -
CONNECTOR J16 -
CONNECTOR J17 -
J4:
CONNECTOR
Terminals
Input/Output
AUX. DEVICES
8 - 10
POWER SUPPLY
CONNECTOR J19 and J20:
Terminals
Input/Output
SENSORS POWER
11 - 12
SUPPLY
INTERNAL OR EXTERNAL
13 - 14
SENSOR (N.O. contact)
Incoming and outgoing
traffic, with partial opening
and closing
Incoming and outgoing
traffic, with partial
"PHARMACY" opening
connection to TLINETD.
Description
- 5 V DC
signals the communication between T-LINETD and DC20
signals the communication between T-LINETD and DC20
+ 5 V DC
optional.
external accessory supply connection.
encoder connection.
transformer secondary connection.
motor connection.
input connection.
input connection.
connection to TLINESELF
Description
8 = 12V DC
9 = 24V DC
10 = - Common
Door StatusFunction
11= 24V DC
12= - GND
Closed
Opening
Closing
Open
In pause
Outside Radar
Inside Radar
Close (Latching Relay)
Emergency
Outside Radar
Inside Radar
Close (Latching Relay)
Emergency
Opens in "EXIT ONLY" and "AUTO".
None.
It reverses the movement and opens in "EXIT ONLY"
(connector J19) or "ENTRY ONLY" (connector J20) and
"AUTO" mode.
Door won't close until sensor is released.
None.
20
The control board
DC20 can be set up
to "pharmacy mode"
only through the
TLINETD device
loading