Bosch CRI Manual Original página 5

Juego de comprobación para medición carrera a carrera
Ocultar thumbs Ver también para CRI:
Idiomas disponibles

Idiomas disponibles

4. Tighten the pressure sensor by the adapter's hex nut.
Torque 20 ±2 Nm.
Fig. 3:
Tightening the pressure sensor
5. Repeat this process until all pressure sensors have
been installed.
Pressure sensors are installed.
"
4.2
Connecting the pressure sensors
When connecting the pressure sensors to the
i
control electronics, make sure to comply with the
channel assignments (injector A to channel A, etc.).
B31
B32
A
B
Fig. 4:
Connecting the pressure sensors
1. Connect connecting cable B31 to the pressure sensor
of channel A.
2. Connect connecting cable B32 to the pressure sensor
of channel B.
3. Connect connecting cable B33 to the pressure sensor
of channel C.
4. Connect connecting cable B34 to the pressure sensor
of channel D.
Pressure sensors are connected.
"
Robert Bosch GmbH
20 ±2 Nm
B33
B34
C
D
Preparation for testing | CRI/CRIN SST | 5 |
5.
Switching on
WARNING – risk of injury from escaping
test oil or ejected parts!
If the hydraulic connection for the test
equipment and the unit to be tested has
not been made properly, test oil may es-
cape under high pressure or parts of the
test equipment may burst on starting the
test. This may cause injury or damage to
property.
Before switching the system on, make
c
sure all hose assemblies on the test
equipment and the unit to be tested are
properly connected.
Do not open the protective door until
c
the DCI drive motor has stopped.
Replace any leaky or defective hose
c
assemblies.
6.
Checking CRI/CRIN SST
For further information see Help Center DCI 700.
i
https://help.boschdiagnostics.com/DCI700/#/home/SST/en/default
7.
Troubleshooting
For further information see Help Center DCI 700.
i
https://help.boschdiagnostics.com/DCI700/#/home/ErrorMessagesSST/en/default