Bosch CRI Manual Original página 4

Juego de comprobación para medición carrera a carrera
Ocultar thumbs Ver también para CRI:
Idiomas disponibles

Idiomas disponibles

en
| 4 | CRI/CRIN SST | Product description
3.
Product description
3.1
Intended
use
The tester set CRI/CRIN SST expands the test scope of
injectors with DCI 700. The tester set CRI/CRIN SST can
be used to determine shot-to-shot scatter of injectors.
For your own safety and to prevent damage to the
device as the result of improper operation, read and
follow the original operating instructions carefully.
3.2
Target group
The product may only be used by trained and instruct-
ed personnel. Apprentices or personnel undergoing
training or instruction may use the product only under
the continuous supervision of an experienced person.
Children must be supervised to make sure they will
not play with the product.
Only personnel
with sufficient knowledge and expe-
rience in hydraulics
is allowed to work on hydraulic
devices.
Instruction on testing diesel components at the Robert
Bosch training center is mandatory.
3.3
Scope of delivery
Designation
4x pressure sensor with magnetic stud
1x connecting cable for 2 pressure sensors
1x connecting cable for 2 pressure sensors
10x cable ties
1)
1x operating instructions
1x assembly instructions 
2)
1) Fitted at the factory on product variant DCI 700 USA/Canada
(0 683 725 003).
2) Not for product variant DCI 700 USA/Canada (0 683 725 003)
The order numbers listed in the section "Scope of
i
delivery" are given for information purposes only.
|
1 689 989 563
2023-08-01
4.
4.1
When screwing the pressure sensor in or out,
!
always apply the wrench to the adapter's hex nut
(see also fig. 3).
Ensure cleanliness when working on sealing com-
!
ponents. Particles on the sealing surfaces may
damage the pressure sensor.
1. Remove the screw plug (1) from the pressure sensor
mount (2) at the high pressure connection.
Order number
Fig. 1:
1 687 231 266
2. Clean the sealing surfaces in the pressure sensor
1 684 466 048
1)
1 684 466 049
mount at the high-pressure connection and on the
1)
1 681 316 008
pressure sensor.
1 689 989 563
3. Screw the pressure sensor (1) into the pressure
1 689 978 675
sensor mount (2) at the high-pressure connection.
Fig. 2:
Preparation for testing
Installing the pressure sensors
1
2
Removing the screw plug
2
Installing the pressure sensor
1
Robert Bosch GmbH
loading

Este manual también es adecuado para:

Crin sst