9.1.1 Adjustment (fig. 7 + 15)
• Turn the adjustment knob for cutting depth (13) to
set the height of the feed table. The set cutting depth
can be read off the scale (H).
• Loosen the parallel stop (8) with the clamping crew
(8a). Adjust the desired angle. The adjusted angle
can be read off the scale (I). Fix the parallel stop (8)
with the clamping screw (8a) after adjustment.
9.1.2 Surface planing mode (Fig. 20/21)
Attention! Watch out the right mounting of the
chip extractor (point 8.5)
• (Narrow workpieces see fig. 21) Open the knurled
srcew (10) and slide the planer blade cover (9) as far
as the width of the workpiece requires. Then tighten
the knurled srcew (10) again.
• (Width, flat workpieces see fig. 20) Open the star
knob nut (4) and set the planer blade cover com-
pletely. (9) is just as high as the workpiece is thick.
The planer blade cover (9) covers the entire blade
roller! Tighten the star knob nut (4) again.
• Plug in the machines power cord ( Press the green
button "I" to start the plane (1).
• Place the workpiece you wish to plane on the feed
table (14). Slide the workpiece as far as possible
with the push stick (16) forwards towards the planing
table (7) over the knives (25).
• When you have finished work, switch off the ma-
chine. To do this, press the red button "0". Then dis-
connect the machine from the mains supply.
• Remove the chips and dust from the feed table (14),
planing table (7) and knife block after the machine
has reached a complete standstill.
• Move the planing knife cover (9) back into position
and cover the entire length of the planing knife.
9.2 Thicknessing
m
IMPORTANT!: Pull out the power plug before
performing any maintenance, cleaning and adjusting
work.
9.2.1 Adjustment (fig. 22)
• Place the crank handle (12) on the spindle and turn
it to adjust the thicknessing table (21) to the required
height. The set angle can be read off the scale (G).
• It is important to adjust the height of the planing ta-
ble (21) from bottom to top, i.e. crank the table fur-
ther down (approx. 5 mm) than the desired height.
Then crank the table (21) upwards to the desired
height.
9.2.2 Thicknessing mode (fig. 22 + 9)
Attention! Watch out the right mounting of the chip ex-
tractor (point 8.7)
• Plug in the machines power cord. Press the green
button "I" to start the plane (2).
• Place a workpiece on the thicknessing table (21).
Guide the workpiece towards the feed table (14).
• When you have finished work, switch off the ma-
chine. To do this, press the red button "0". Then dis-
connect the machine from the mains supply.
• Remove the chips and dust from the thicknessing
table (21) and knife block after the machine has
reached a complete standstill.
10. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
Important information
In the event of an overloading the motor will switch it-
self off. After a cool-down period (time varies) the mo-
tor can be switched back on again.
Damaged electrical connection cable.
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be
used and are life-threatening due to the insulation damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.