Environmental temperature: 40° C max/4° C min (average: 30°C)
Altitude: up to 2,000 metres
Relative humidity: Max 30% at 40° C/max 90% at 20° C
Page 10 of 33
DISHWASHER INSTRUCTIONS MANUAL
Warning! Installation must be carried out only by specialised
technicians!
Before connecting the equipment, make sure that both the voltage
and frequency of the mains power supply correspond to those
indicated on the data plate affixed to the side panel of the machine.
To connect the machine to the mains power supply, use only
H07RN-F type power supply cables with a conductor cross-section
appropriate for the maximum absorption indicated on the data plate
and as indicated in the table below.
Take care when laying out the cable to observe the minimum bend
radius indicated by the cable manufacturer.
Current (A)
40
50
63
80
100
125
The machine must be connected to the power supply by means of
a type "C" dedicated automatic omnipolar switch in compliance
with safety regulations in force, or alternatively with a disconnect
switch having fuses with 3 mm minimum opening distance between
contacts. The above-mentioned switch, not supplied with the
machine, must wall-mounted at an easily accessible point, at a
height between 0.6 m and 1.70 m.
Before connecting the machine to the power supply, make sure the
power is switched off at the mains.
Remove the front panel and the cover of the electrical board by
removing the screws.
Feed the power cable through the cable gland on the back of the
machine.
Connect the cable to the terminals on the board, as indicated in the
wiring diagram attached.
If the Neutral and Earth cables are incorrectly connected, this can
result in irreversible damage to the machine, and the warranty may
be invalidated!
Check that the cables on the contactors, thermal protections etc.
are properly tightened, as the screws may have worked loose
during transportation.

Environmental conditions

Cap 5

Electrical connection

H07RN-F
Cross-section
Maximum length (mm)
2
(mm
)
10
16
16
25
35
50
INSTALLATION
5000
MDITT31-(r06)