FAULT DIAGNOSTICS (BATTERY OPERATED MACHINES WITH DRIVE SYSTEM)
The display also shows anomalies by temporarily replacing hour meter monitoring. The main anomalies that may occur are listed in the table below:
Fault diagnostics for "WIKI" Electronic Control Unit
( UP TO SERIAL NUMBER "206497 GO 531T", "206741 GO 552T - 562T")
"See page 54" for "SOLID" ECU diagnostics.
Code displayed
- 20
- 40
- 50
- 60
- 70
- 80
- 90
- 120
- 130
- 140
Fault description
Maximum temperature reached
12T drive
12T suction
12T brushes
Machine in STAND-BY
Battery at minimum power
Battery at maximum power
Brushes stop threshold
Suction stop threshold
Start not at 0
Machine version
Machine with drive system
Machine with drive system
Machine with drive system
Machine with drive system
Machine with drive system
Machine with drive system
Machine with drive system
Machine with drive system
Machine with drive system
Machine with drive system
53