The batteries are housed in the compartment provided in the solution
tank, accessed by raising the recovery liquid tank.
To install the batteries proceed as follows:
•
Make sure that the recovery tank is completely empty.
•
Disconnect the connections 1 and 2 of the vacuum motor hose
and the squeegee hose respectively.
•
Remove the recovery tank.
•
Place the batteries in the compartment and connect them as
shown battery connecting diagram.
•
Connect the battery connector 3 to the machine connector 4.
•
Return the recovery tank to its original position.
•
Reconnect the connections 1 and 2 to the fi lter cover and the
recovery tank respectively.
!
Caution!
THE MACHINE CAN BE FITTED WITH "LEAD-ACID" and/or "GEL"
BATTERIES.
For the battery operated machines with drive-system, one must
change some parameters on the electronic control board (see
"BATTERY PARAMETERS CONFIGURATION"). For the battery
operated machines without drive-system, one must replace bat-
tery indicator light 2 (fi g.2) with a new one predisposed for GEL
batteries.
INSTALLING THE BATTERIES (FIG.4)
44
2
3
4
1