Installing The Batteries - RCM GO Serie Manual De Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

The batteries are housed in the compartment provided in the solution
tank, accessed by raising the recovery liquid tank.
To install the batteries proceed as follows:
Make sure that the recovery tank is completely empty.
Disconnect the connections 1 and 2 of the vacuum motor hose
and the squeegee hose respectively.
Remove the recovery tank.
Place the batteries in the compartment and connect them as
shown battery connecting diagram.
Connect the battery connector 3 to the machine connector 4.
Return the recovery tank to its original position.
Reconnect the connections 1 and 2 to the fi lter cover and the
recovery tank respectively.
!
Caution!
THE MACHINE CAN BE FITTED WITH "LEAD-ACID" and/or "GEL"
BATTERIES.
For the battery operated machines with drive-system, one must
change some parameters on the electronic control board (see
"BATTERY PARAMETERS CONFIGURATION"). For the battery
operated machines without drive-system, one must replace bat-
tery indicator light 2 (fi g.2) with a new one predisposed for GEL
batteries.
INSTALLING THE BATTERIES (FIG.4)
44