JUMO flowTRANS MAG H20 Manual Breve página 47

Ocultar thumbs Ver también para flowTRANS MAG H20:
Idiomas disponibles

Idiomas disponibles

5
Installation
5.1
Preparing for installation
5.1.1
Installation site
The device is protected against electromagnetic interference.
The device is protected from UV radiation.
The device is protected from the weather when used outside.
5.1.2
Inlet and outlet sections
No straight inlet or outlet sections are required to operate the device.
5.1.3
Installation position
Flow direction
5.1.4
Avoid mechanical strain
Install the device free of mechanical stress so that no pipeline forces can be transmitted to the device.
Important:
Take into account the insertion length of the device including the two pipe adapters (X).
Ensure that the center lines of both ends of the pipes (1) align before installing the device in the pipe.
The surfaces A must be parallel to each other.
The ends of the pipe must be perpendicular to the surfaces A.
Correct
5 Installation
False
15
loading