Blank display . Thermometer
does not have power .
System Error - self-check display
flashes continuously and will not
be followed by the ready beep
and the ready symbol .
If error persists .
If error still persists .
Care and cleaning
Use an alcohol swab or cotton swab moistened with alcohol (70% isopropyl) to
clean the thermometer casing and the measuring probe . Ensure that no liquid
enters the interior of the thermometer . NEVER use abrasive cleaning agents,
thinners or benzene for cleaning and NEVER immerse the instrument in water
or other cleaning liquids . Wait 10 minutes after cleaning before taking a
temperature measurement .
NEVER insert a sharp object into the scanner area or any other open surface on
the thermometer .
Replacing the batteries
Replace with 2 new AAA batteries when the flashing battery symbol appears on
the LCD screen . To change the batteries, slide open the battery cover and
remove batteries . Replace the batteries being sure to align properly as indicated
inside the battery compartment . Remove the batteries from the product if not
used for extended periods of time in order to avoid damage to the thermometer
resulting from a leaking battery .
To protect the environment, dispose of empty batteries at appropriate
collection sites according to national or local regulations .
Do not mix alkaline, standard, or rechargeable batteries
1 Year Limited warranty
This product comes with a 1 year limited warranty commencing on the date of
purchase . Within the warranty period we will eliminate, free of charge, any
defects in the appliance resulting from faults in materials or workmanship, by
replacing the complete appliance .
10
Please check if the
batteries have been
loaded correctly . Also
check polarity (<+> and
<–>) of batteries .
Contact customer
service if thermometer
still does not function .
Wait 1 minute until the
thermometer turns off
automatically, then turn
on again .
. . . r est the thermometer
by removing the batteries
and putting them back in .
. . .please contact
customer service .
This warranty is applicable only for the appliance supplied by the appointed
distributor . This warranty does not cover: damage due to improper use, normal
wear or use as well as defects that have a negligible effect on the value or
operation of the appliance . The warranty becomes void if repairs are
undertaken by unauthorized persons and if original Braun parts are not used .
Calibration
The thermometer is initially calibrated at the time of manufacture . If this
thermometer is used according to the use instructions, periodic re-adjustment
is not required . If at any time you question the accuracy, please contact
Consumer Relations .
Product specification
Type:
Measuring range:
Measuring location:
Resolution:
Laboratory accuracy
- Body temperature mode:
- Food/bath temperature mode:
(non-medical use)
Clinical accuracy:
Display:
Acoustic:
Operating temperature:
Automatic Switch-off:
Weight:
Size:
Long term storage ranges
Storage/transport temperature:
English
Non-contact forehead thermometer
(BNT100)
Body: 34 . 0 °C – 43 . 0 °C (93 . 2 °F – 109 . 4 °F)
Surface: 0 °C – 100 .0 °C
(32 .0 °F – 212 .0 °F)
Forehead
0 .1 °C (0 .1 °F)
±0 .2 °C for the range 35 .0 °C – 42 .0 °C
(±0 .4 °F for 95 .0 °F – 107 .6 °F)
±0 .3 °C (±0 .5 °F) for the range outside
35 .0 °C – 42 .0 °C (95 .0 °F – 107 .6 °F)
±2 .0 °C for the range 0 .0 °C – 100 .0 °C
(±3 .6 °F for 32 .0 °F – 212 .0 °F)
Clinical performance and protocols are
available upon request
This thermometer displays a calculated
oral equivalent estimate
Liquid Crystal Display, 4 digits plus
special icons
Audio:
Normal temp range = Green temp
range: 1 long beep for 0 .4 second
duration
Fever = Yellow temp range: 1 long
beep for 0 .4 second duration
High fever = Red: 10 short beeps
(0 .02 seconds on, 0 .13 seconds off )
15 °C – 40 °C (59 .0 °F to 104 °F)
Within approx . 20 seconds
93 .2g (w/ batteries) and
71 .5 (w/o batteries)
55mm x 38mm x 149mm
-25 °C to 55 °C (-13 °F to 131 °F )
11