Electrical connection

EVEN THE TINIEST PROCEDURE
OF AN ELECTRICAL NATURE
MUST BE CARRIED OUT BY PRO-
FESSIONALLY
STAFF .
As envisaged by the regulations in force, the machine is
not equipped with a master circuit breaker, but simply
has a plug-socket connection to the electrical mains.
The machine is supplied with 3 mt. of free cable. A plug
corresponding to the following requirements must be
connected to the cable:
• Conformity to Norm IEC 309
• 230/400 Volt – 16A
• 2P + Ground
• IP 44
VERSION WITH
MONOPHASE MOTOR
On delivery, the machine is preset to operate at a voltage
of 200 ÷ 265 V - 50/60 Hz monophase.
INSTRUCTION, USE AND
MAINTENANCE MANUAL
9.4
After the delivery, the machine is prearranged to operate
on wheel of 41" maximum diameter and a rim diameter
(10" - 26"). It's possible to move the tools column to
enlarge the working area from 43" (with rim diameter of
QUALIFIED
12" - 28") to 45" (with rim diameter of 14" - 30") (see
Figure 10).
The column handling is possible unscrewing the fixing
screws of the base (Fig. 10 pos. A) to the column (Fig.
10 pos. B) and sliding the base (Fig. 10 pos. A) into the
proper slots until the required measure.
1. To remove the lateral guard (Fig. 11 pos. 1-2) of the
2. To unscrew the screws (Fig. 11 pos. 3) and the nuts
3. To remove six remained screws (Fig. 11 pos. 5).
4. To move the base (Fig. 11 pos. 6) into the required
5. To lock the base three screws (Fig. 11 pos. 3) with a
6. To place six screws (Fig. 11 pos. 5) previously re-
Page 30 of 106
KENDO.30LIGHT-KENDO.30LIGHTFI

Working area modification

Fig. 10
MAKE SURE THAT THE TYRE
CHANGING MACHINE COLUMN IS
STABLE USING A CABLE WITH A
BLOCK TO LOCK ON THE LIFTING
CROSS BEAM (FIG. 11 POS. 7).
machine.
near the central slots (Fig. 11 pos. 4) playing atten-
tion to not remove the nuts from the proper screws.
position (to 43" or 45") and if necessary to use a lift-
ing device (Fig. 11 pos. 7).
couple of 80 Nm.
moved and to lock them on the base side with a cou-
ple of 80 Nm.