CRP-40.book Seite 30 Montag, 27. September 2010 4:07 16
Setting up and connecting the refrigerator
6.3
Changing the door hinge
You can also change the hinge of the door, so that it opens to the left rather
than the right.
➤ Proceed as shown in fig. 6, page 5 to fig. 8, page 6, to change the
hinges.
6.4
Connecting to a battery
The refrigerator can be operated with a 12 V to 24 V DC voltage supply.
e
Caution!
To prevent voltage and power losses, the cable should be as short
as possible and not be interrupted.
For this reason avoid additional switches, plugs or socket strips.
➤ Determine the required cross section of the cable in relation to the cable
length according to fig. 9, page 6.
Key for fig. 9, page 6
Co-ordinate axis
l
∅
e
Caution!
Make sure that the polarity is correct.
➤ Before starting up the appliance for the first time, check whether the op-
erating voltage and the battery voltage match (see type plate).
➤ For the electrical connection you also need the wiring diagram (fig. 0,
page 7).
No. in fig. 0,
page 7
1
2
3
4
30
Meaning
Cable length
Cable cross section
Meaning
Electronic terminal rail
Compressor
DC fan (if present)
Mechanical thermostat
CoolMatic CRP-40
Unit
m
mm²