12. Parameter configuration
12.1. Available parameters
Parameter no.
Parameter function
Kiln performance
14
display in kW
Additional switch
45
output 230 V
(ST 411 only)
Logging interval data
50
on USB in s
Temperature display
60
in °C or °F
12.2. Changing parameters
Step
Display
1
8.8.8.8.
2
tC.S
3
tC.S
4
P14-
5
P45-
6
0
7
1
8
Min. value
0
0
5
0
Icon
Description
Switching the control unit off
Switch on the control unit and
j
press the
key at the same
time.
Hold down the
set thermocouple type is shown
in the main display.
j
Release the
The main display shows the first
configurable parameter.
The parameter to be configured
can be selected by pressing the
d
f
and
keys.
The set value of the parameter
to be configured can be called
g
up with the
This can be altered by pressing
d
f
the
&
keys.
77 / 291 - EN -
Max.
Default setting
value
9999
0
1
1
300
60
1
0
Remark
The thermocouple type is only
j
displayed and cannot be changed
key until the
here.
The thermocouple is preconfigured
at the factory.
key.
key.
Description of the
value
1 unit = 0.1 kW
E.g.:
For a kiln with an output
of 10 kW (see kiln
nameplate), enter the
value "100".
0 = disabled
1 = event
2/3 = ATTENTION:
Parameter 2 or 3 must
not be used if it is
available!!!
1 unit = 1 s (second)
0 =°C
1 = °F