4.2 Connecting the power supply/power source communication connection cable
Fire hazard due to dirty connection
Dirty connections may cause a short circuit, resulting in a fire. This may result in serious burns.
► Ensure that the interfaces are clean.
When the connections are not in use, cover the interfaces with the protective caps.
4.3 Establishing the welding tractor's power supply
► Observe the safety instructions in the operating instructions for the welding power source.
► Observe the safety instructions in the operating instructions for the welding tractor.
► Refer to the operating instructions for the welding power source, the welding tractor, and the circuit
diagrams for the mains voltage and fuse protection.
WARNING
4 Installing ABICAR POWER PAK
Plug the power supply/power source
1
communication from the welding torch cable
assembly into the communication connecting
socket on the wire feed unit.
Plug the ABICAR connection cable for the power
2
supply/power source communication into the
communication connecting socket on the
welding torch cable assembly (on the torch side).
Plug the other end of the ABICAR connection
3
cable for the power supply/power source
communication into the communication
connecting socket on the welding tractor.
To disconnect the cables, hold down the release
4
and then pull out.
Plug in the mains plug.
1
Set the main switch on the welding power source to <I>.
2
Set the <ON/OFF> switch on the iMIG POWER 400
3
POWER MODULE to <ON> to switch on the power
supply to the welding tractor. The green LED lights up.