A 2 wire switch (e.g. a reed switch) is connected to pin 1 and 5.
A sensor with PNP output is connected to pin 1, 2 and 5.
Configurable digital inputs and outputs (DIGITAL I/O)
15-pole D-sub socket connector for configurable signals.
Use a 15-pole D-sub pin plug.
Voltage range
Input resistance
Output resistance
Output current protection
Input response time
Output response time
NOTICE
• If the max. current is exceeded, the output voltage will switch off. This
can be resolved by switching the output off and on again.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
I/O
INT 24V
EXT-OUT-COM0
EXT-OUT0
EXT-OUT1
EXT-OUT2
EXT-OUT3
EXT-IN0
EXT-IN1
EXT-IN2
EXT-IN3
EXT-IN-COM0
DGND
© Atlas Copco Industrial Technique AB - 9836 791600 00
EN
11-30 VDC
>5 kΩ
23-35 Ω
120 mA max. peak/continuous current, over current
protected.
<25 ms (with de-bouncing filter)
<5 ms
Description
Internal 24 V supply
External common line for
outputs
Configurable
Configurable
Configurable
Configurable
Not used
Configurable
Configurable
Configurable
Configurable
Not used
Not used
External common line for
inputs
Internal ground
Installation
Default
Busy
Tightening OK
Tightening NOK
Batch OK
Start tightening
Reset tool
Start loosening
Reset batch