Installation
For information on configuration on the outputs and inputs, see ToolsTalk MT
- Reference - I/O status.
NOTICE
• All inputs are opto isolated.
• If used to reset the tool, the signal duration must be more than 40 ms.
• Interface connection can be connected in PNP mode (source type, posi-
tive logic), or in NPN mode (sink type, negative logic).
PNP mode
I/O
INT -24V
EXT-OUT-COM0
EXT-OUT0...EXT- OUT3
EXT-IN0...EXT- IN3
EXT-IN-COM0
DGND
NPN mode
10
EN
Description
+24 V output
Connect to INT +24V
or external +24 V
(not at the same time)
The outputs will be connected to the external +24 V
when activated.
The inputs will be activated by a +24 V signal applied
to the input pin.
Connect to DGND
or external 0 V.
0 V output