Leuze AMS 107i Manual De Instrucciones página 21

Ocultar thumbs Ver también para AMS 107i:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
Supply voltage
Current consumption
Light source / Wavelength Laser / red
Laser class
Wavelength
Max. output power (peak) 4 mW
Impulse duration
Measurement range
Accuracy
Traverse rate
Interface type
Switching inputs/outputs
Degree of protection
VDE protection class
Housing
Optics cover
Weight
Ambient temperature
– Operation
– Storage
– Heated model
Rel. air humidity
Vibration
Noise
Shock
Electromagnetic compati-
bility
AMS 107i 40
18 ... 30 V DC
≤  250 mA / 24 V DC
2 (acc. to IEC 60825-1:2014)
660 nm
≤ 0.8 μs
0.1 ... 40 m
±2 mm
≤ 10 m/s
SSI
2, configurable
IP65 (acc. to EN 60529)
with screwed-on M12 connectors or mounted caps
III
Diecast aluminum
Glass
Approx. 1 kg
-5 °C ... +60 °C
-30 °C ... +70 °C
-30 °C ... +60 °C
Max. 90 %, non-condensing
IEC 60068-2-6, test Fc
IEC 60068-2-64
IEC 60068-2-27, test Ea
EN 61000-6-2
EN 61000-6-4
AMS 107i 120
0.1 ... 120 m
EN
21
loading